CISCO-IF-MONITOR-NOTIF-MIB :: cIfMonNotifCount

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-IF-MONITOR-NOTIF-MIB › cIfMonNotifCount

cIfMonNotifCount

Module: CISCO-IF-MONITOR-NOTIF-MIB

OID (symbolic): CISCO-IF-MONITOR-NOTIF-MIB::cIfMonNotifCount

OID (numeric): 1.3.6.1.4.1.9.10.999.1.1

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This object will be incremented and included in the varbind list of the cIfMonNotifEvent notification. This object is guaranteed to increase once per notification originated from the MIB.

NMSes should track the value of this object received in each notification. If the difference in the value of this object across two consecutive notifications is more than one, a notification has been delayed, dropped, lost or routed out of sequence. The only reliable way to recover such notifications is via the NOTIFICATION-LOG-MIB. The NMS should preferably configure/create a log in the NOTIFICATION-LOG-MIB to capture cIfMonNotifEvent notifications. If possible, a named log should be created. When a notification loss is detected, the NMS can then poll the log to determine which notification was lost. The reader can look up RFC 3014 for more information on the NOTIFICATION-LOG-MIB.

In addition to tracking the value of this object in each notification, the NMS should periodically poll this object. If the polled value of this object is two or more counts greater than the value from the last received notification, a notification has likely been dropped, and the NMS must use the NOTIFICATION-LOG-MIB to poll for the dropped notification.

What is cIfMonNotifCount?

A counter that increases each time an interface-monitoring notification is generated, letting an NMS detect if any notifications were missed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.10.999.1.1
snmpwalk -v2c -c public <target> CISCO-IF-MONITOR-NOTIF-MIB::cIfMonNotifCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.10.999.1.1.1
snmpget -v2c -c public <target> CISCO-IF-MONITOR-NOTIF-MIB::cIfMonNotifCount.1

Start monitoring Cisco routers and switches (interface error thresholds) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-IF-MONITOR-NOTIF-MIB::cIfMonNotifCount OID value, configure state conditions and alerts, and monitor any Cisco routers and switches (interface error thresholds) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.10ciscoExperimentCISCO-SMI
1.3.6.1.4.1.9.10.999ciscoCableDsgIfMIBCISCO-CABLE-DSG-IF-MIB
1.3.6.1.4.1.9.10.999.1ccdsgIfCaVendorCISCO-CABLE-DSG-IF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.10.999.1.1cIfMonNotifCountCISCO-IF-MONITOR-NOTIF-MIB