CISCO-ENVMON-MIB :: ciscoEnvMonTemperatureStatusValue

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-ENVMON-MIB › ciscoEnvMonTemperatureStatusValue

ciscoEnvMonTemperatureStatusValue

Module: CISCO-ENVMON-MIB

OID (symbolic): CISCO-ENVMON-MIB::ciscoEnvMonTemperatureStatusValue

OID (numeric): 1.3.6.1.4.1.9.9.13.1.3.1.3

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The current measurement of the testpoint being instrumented.

What is ciscoEnvMonTemperatureStatusValue?

Reports the current temperature reading, in degrees Celsius, measured at the associated test point on the device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.13.1.3.1.3
snmpwalk -v2c -c public <target> CISCO-ENVMON-MIB::ciscoEnvMonTemperatureStatusValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.13.1.3.1.3.1
snmpget -v2c -c public <target> CISCO-ENVMON-MIB::ciscoEnvMonTemperatureStatusValue.1

Start monitoring Cisco routers and switches with environmental monitoring hardware with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ENVMON-MIB::ciscoEnvMonTemperatureStatusValue OID value, configure state conditions and alerts, and monitor any Cisco routers and switches with environmental monitoring hardware from a single console.

How to Use in IPNetwork Monitor

Select a Cisco routers and switches with environmental monitoring hardware as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ciscoEnvMonTemperatureStatusValue into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The current measurement of the testpoint being instrumented. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.13ciscoEnvMonMIBCISCO-ENVMON-MIB
1.3.6.1.4.1.9.9.13.1ciscoEnvMonObjectsCISCO-ENVMON-MIB
1.3.6.1.4.1.9.9.13.1.3ciscoEnvMonTemperatureStatusTableCISCO-ENVMON-MIB
1.3.6.1.4.1.9.9.13.1.3.1ciscoEnvMonTemperatureStatusEntryCISCO-ENVMON-MIB
1.3.6.1.4.1.9.9.13.1.3.1.3ciscoEnvMonTemperatureStatusValueCISCO-ENVMON-MIB