CISCO-ENTITY-DIAG-MIB :: ceDiagTestPerfTotalRuns

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-ENTITY-DIAG-MIBceDiagTestPerfTotalRuns

ceDiagTestPerfTotalRuns

Module: CISCO-ENTITY-DIAG-MIB

OID (symbolic): CISCO-ENTITY-DIAG-MIB::ceDiagTestPerfTotalRuns

OID (numeric): 1.3.6.1.4.1.9.9.350.1.6.1.1.7

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This object indicates the total number of times the corresponding physical entity has executed the test.

What is ceDiagTestPerfTotalRuns?

Counts the total number of times the physical entity has executed a given diagnostic test.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.350.1.6.1.1.7
snmpwalk -v2c -c public <target> CISCO-ENTITY-DIAG-MIB::ceDiagTestPerfTotalRuns

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.350.1.6.1.1.7.1
snmpget -v2c -c public <target> CISCO-ENTITY-DIAG-MIB::ceDiagTestPerfTotalRuns.1

Start monitoring Cisco modular chassis switches/routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ENTITY-DIAG-MIB::ceDiagTestPerfTotalRuns OID value, configure state conditions and alerts, and monitor any Cisco modular chassis switches/routers from a single console.

How to Use in IPNetwork Monitor

Select a Cisco modular chassis switches/router as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ceDiagTestPerfTotalRuns into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object indicates the total number of times the corresponding physical entity has executed the test. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.350ciscoEntityDiagMIBCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1ciscoEntityDiagMIBObjectsCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1.6ceDiagTestCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1.6.1ceDiagTestPerfTableCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1.6.1.1ceDiagTestPerfEntryCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1.6.1.1.7ceDiagTestPerfTotalRunsCISCO-ENTITY-DIAG-MIB