CISCO-ENTITY-DIAG-MIB :: ceDiagTestAttributes

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-ENTITY-DIAG-MIBceDiagTestAttributes

ceDiagTestAttributes

Module: CISCO-ENTITY-DIAG-MIB

OID (symbolic): CISCO-ENTITY-DIAG-MIB::ceDiagTestAttributes

OID (numeric): 1.3.6.1.4.1.9.9.350.1.1.1.1.3

Node type: OBJECT-TYPE

Type: Bits

Access: read-only

Description: This object indicates a set of attributes characterizing the test:

'minimal' - indicates that this test will be executed during boot-up if ceDiagBootupLevel is set to 'minimal' or 'complete'. This test is also included in the minimal or complete test suites.

'complete' - indicates that this test will be executed during boot-up if ceDiagBootupLevel is set to 'complete'. This test is also included in the complete test suites.

'perPort' - indicates that this test is a executed for each port contained by the module. This test is also included in the perPort test suites.

'fatal' - indicates that if this test fails, then the diagnostic should fail indicating that a major error occurred.

'basicOnDemand' - indicates that this test will be run during the basic on demand job is run.

'standby' - indicates that this test can only be run if the physical entity is a standby unit and can only be executed from the standby unit.

'parallel' - indicates that this test can be executed in parallel with other tests without checking for resource availability.

'nonDisruptive' - indicates this test can be executed without disrupting the physical entity's normal operation. This test is also included in the nonDisruptive test suites.

'hmAlwaysEnabled' - indicates that a management application can not disable the use of this test for the purpose of health monitoring.

'hmFixedInterval' - indicates that a management application can not change the interval at which health monitoring executes this test.

'nonHM' - indicates that this test can not be used for health monitoring.

'proxy' - indicates that the test must be executed through a proxy.

'activeToStandby' - indicates that this test can only be run if the physical entity is a standby unit and can only be executed from the active unit.

'offline' - indicates that this test will not get a user confirmation when it is run.

'perDevice' - indicates that this test is a per device test.

'disruptive' - indicates that this test can be executed with disrupting the physical entity's normal operation. This test is also included in the disruptive test suites.

What is ceDiagTestAttributes?

A read-only set of attributes characterizing a diagnostic test, such as whether it runs at boot-up based on the configured boot-up level.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.350.1.1.1.1.3
snmpwalk -v2c -c public <target> CISCO-ENTITY-DIAG-MIB::ceDiagTestAttributes

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.350.1.1.1.1.3.1
snmpget -v2c -c public <target> CISCO-ENTITY-DIAG-MIB::ceDiagTestAttributes.1

Start monitoring Cisco modular chassis switches/routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ENTITY-DIAG-MIB::ceDiagTestAttributes OID value, configure state conditions and alerts, and monitor any Cisco modular chassis switches/routers from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.350ciscoEntityDiagMIBCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1ciscoEntityDiagMIBObjectsCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1.1ceDiagDescriptionsCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1.1.1ceDiagTestInfoTableCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1.1.1.1ceDiagTestInfoEntryCISCO-ENTITY-DIAG-MIB
1.3.6.1.4.1.9.9.350.1.1.1.1.3ceDiagTestAttributesCISCO-ENTITY-DIAG-MIB