CISCO-CABLE-DIAG-MIB :: ccdPrbsIfTestErrors

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-CABLE-DIAG-MIB › ccdPrbsIfTestErrors

ccdPrbsIfTestErrors

Module: CISCO-CABLE-DIAG-MIB

OID (symbolic): CISCO-CABLE-DIAG-MIB::ccdPrbsIfTestErrors

OID (numeric): 1.3.6.1.4.1.9.9.390.1.1.1.1.3

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Indicates the number of errors which occurred during the current or most recent running of a test. This Gauge is reset to zero each time a test starts (e.g., when ccdPrbsIfAction is set to 'start') or each time ccdPrbsIfAction is set to 'errorReset' on an interface.

If and when an instance of ccdPrbsIfTestErrors reaches its maximum value as indicated by the corresponding instance of ccdPrbsIfTestErrorsMaxValue, its value will be less or equal to the actual number of errors.

What is ccdPrbsIfTestErrors?

This read-only gauge counts the bit errors detected during the current or most recent PRBS test run on the interface, resetting to zero whenever the test starts or is explicitly cleared.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.390.1.1.1.1.3
snmpwalk -v2c -c public <target> CISCO-CABLE-DIAG-MIB::ccdPrbsIfTestErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.390.1.1.1.1.3.1
snmpget -v2c -c public <target> CISCO-CABLE-DIAG-MIB::ccdPrbsIfTestErrors.1

Start monitoring Cisco Catalyst-family LAN switches (copper cable diagnostics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-CABLE-DIAG-MIB::ccdPrbsIfTestErrors OID value, configure state conditions and alerts, and monitor any Cisco Catalyst-family LAN switches (copper cable diagnostics) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco Catalyst-family LAN switch (copper cable diagnostics) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ccdPrbsIfTestErrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. Indicates the number of errors which occurred during the current or most recent running of a test. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.390ciscoCableDiagMIBCISCO-CABLE-DIAG-MIB
1.3.6.1.4.1.9.9.390.1ciscoCableDiagMIBObjectsCISCO-CABLE-DIAG-MIB
1.3.6.1.4.1.9.9.390.1.1ccdPrbsObjectsCISCO-CABLE-DIAG-MIB
1.3.6.1.4.1.9.9.390.1.1.1ccdPrbsIfTableCISCO-CABLE-DIAG-MIB
1.3.6.1.4.1.9.9.390.1.1.1.1ccdPrbsIfEntryCISCO-CABLE-DIAG-MIB
1.3.6.1.4.1.9.9.390.1.1.1.1.3ccdPrbsIfTestErrorsCISCO-CABLE-DIAG-MIB