CISCO-ATM2-MIB :: ciscoatmInterfaceCurrentMaxSvpcVpi

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-ATM2-MIB › ciscoatmInterfaceCurrentMaxSvpcVpi

ciscoatmInterfaceCurrentMaxSvpcVpi

Module: CISCO-ATM2-MIB

OID (symbolic): CISCO-ATM2-MIB::ciscoatmInterfaceCurrentMaxSvpcVpi

OID (numeric): 1.3.6.1.4.1.9.10.23.1.3.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The maximum VPI that the signalling stack on the ATM interface may currently allocate to switched virtual path connections. This value is the minimum of ciscoatmInterfaceConfMaxSvpcVpi, and the ciscoatmInterfaceConfMaxSvpcVpi of the interface's UNI/NNI peer.

If the interface does not negotiate with its peer to determine the maximum VPI that can be allocated to SVPCs on the interface, then the value of this object must equal ciscoatmInterfaceConfMaxSvpcVpi.

What is ciscoatmInterfaceCurrentMaxSvpcVpi?

This read-only value reports the maximum VPI the signalling stack may currently allocate to switched virtual path connections, computed as the minimum of this interface's own configured maximum and its UNI/NNI peer's configured maximum, or a fixed value if the interface doesn't negotiate. Because it's the minimum of both sides, this is the actual usable ceiling for new switched virtual paths right now, and it can be lower than what was configured locally if the peer is more restrictive, exactly the object to check when SVPC setups are being rejected for exceeding VPI range despite a seemingly generous local configuration. A local configuration of 20 combined with a peer only willing to negotiate up to 8 would leave this object reading 8, and any SVPC setup attempt requesting VPI 15 would fail.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.10.23.1.3.1.17
snmpwalk -v2c -c public <target> CISCO-ATM2-MIB::ciscoatmInterfaceCurrentMaxSvpcVpi

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.10.23.1.3.1.17.1
snmpget -v2c -c public <target> CISCO-ATM2-MIB::ciscoatmInterfaceCurrentMaxSvpcVpi.1

Start monitoring Cisco routers/switches with ATM interfaces with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ATM2-MIB::ciscoatmInterfaceCurrentMaxSvpcVpi OID value, configure state conditions and alerts, and monitor any Cisco routers/switches with ATM interfaces from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.10ciscoExperimentCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.10.23ciscoAtm2MIBCISCO-ATM2-MIB
1.3.6.1.4.1.9.10.23.1ciscoatm2MIBObjectsCISCO-ATM2-MIB
1.3.6.1.4.1.9.10.23.1.3ciscoatmInterfaceExtTableCISCO-ATM2-MIB
1.3.6.1.4.1.9.10.23.1.3.1ciscoatmInterfaceExtEntryCISCO-ATM2-MIB
1.3.6.1.4.1.9.10.23.1.3.1.17ciscoatmInterfaceCurrentMaxSvpcVpiCISCO-ATM2-MIB