CIENA-CES-RMON-MIB :: cienaCesRmonTransferServerLastPushTime

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-RMON-MIB › cienaCesRmonTransferServerLastPushTime

cienaCesRmonTransferServerLastPushTime

Module: CIENA-CES-RMON-MIB

OID (symbolic): CIENA-CES-RMON-MIB::cienaCesRmonTransferServerLastPushTime

OID (numeric): 1.3.6.1.4.1.1271.2.1.34.1.1.1.1.1.4

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: The time of the last file push.

What is cienaCesRmonTransferServerLastPushTime?

This reports the timestamp of the most recent RMON file push attempt to this server. Comparing this against the configured push interval tells an admin whether pushes are actually happening on schedule; a last-push time that's much older than one interval ago indicates the automatic push job has stalled even if the device itself looks otherwise healthy. For example, if the push interval is set to 3600 seconds (1 hour) but this timestamp is 6 hours old, the scheduled push mechanism has clearly stopped working and needs investigation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.34.1.1.1.1.1.4
snmpwalk -v2c -c public <target> CIENA-CES-RMON-MIB::cienaCesRmonTransferServerLastPushTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.34.1.1.1.1.1.4.1
snmpget -v2c -c public <target> CIENA-CES-RMON-MIB::cienaCesRmonTransferServerLastPushTime.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-RMON-MIB::cienaCesRmonTransferServerLastPushTime OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.34cienaCesRmonMIBCIENA-CES-RMON-MIB
1.3.6.1.4.1.1271.2.1.34.1cienaCesRmonMIBObjectsCIENA-CES-RMON-MIB
1.3.6.1.4.1.1271.2.1.34.1.1cienaCesRmonCIENA-CES-RMON-MIB
1.3.6.1.4.1.1271.2.1.34.1.1.1cienaCesRmonTransferCIENA-CES-RMON-MIB
1.3.6.1.4.1.1271.2.1.34.1.1.1.1cienaCesRmonTransferServerTableCIENA-CES-RMON-MIB
1.3.6.1.4.1.1271.2.1.34.1.1.1.1.1cienaCesRmonTransferServerEntryCIENA-CES-RMON-MIB
1.3.6.1.4.1.1271.2.1.34.1.1.1.1.1.4cienaCesRmonTransferServerLastPushTimeCIENA-CES-RMON-MIB