CIENA-CES-ALARM-MIB :: cienaCesAlarmToMinor

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-ALARM-MIB › cienaCesAlarmToMinor

cienaCesAlarmToMinor

Module: CIENA-CES-ALARM-MIB

OID (symbolic): CIENA-CES-ALARM-MIB::cienaCesAlarmToMinor

OID (numeric): 1.3.6.1.4.1.1271.2.1.24.1.2.1.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: This object indicates the time after which the severity specified by alarmModelState will be escalated to minor.

What is cienaCesAlarmToMinor?

This sets how many seconds an alarm must remain active before this alarm model automatically escalates its own severity to minor. As the first rung of a multi-stage escalation ladder, a short value here means the device is tuned to stop treating brief transient conditions as informational quickly and start surfacing them on NOC dashboards. For example, set to 30, a loss-of-signal condition that clears within 20 seconds never escalates, but one still present at 31 seconds bumps straight to minor severity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.24.1.2.1.1.6
snmpwalk -v2c -c public <target> CIENA-CES-ALARM-MIB::cienaCesAlarmToMinor

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.24.1.2.1.1.6.1
snmpget -v2c -c public <target> CIENA-CES-ALARM-MIB::cienaCesAlarmToMinor.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-ALARM-MIB::cienaCesAlarmToMinor OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.24cienaCesAlarmMIBCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1cienaCesAlarmMIBObjectsCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1.2cienaCesAlarmCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1.2.1cienaCesAlarmTableCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1.2.1.1cienaCesAlarmEntryCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1.2.1.1.6cienaCesAlarmToMinorCIENA-CES-ALARM-MIB