CIENA-CES-ALARM-MIB :: cienaCesAlarmToMajor

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-ALARM-MIB › cienaCesAlarmToMajor

cienaCesAlarmToMajor

Module: CIENA-CES-ALARM-MIB

OID (symbolic): CIENA-CES-ALARM-MIB::cienaCesAlarmToMajor

OID (numeric): 1.3.6.1.4.1.1271.2.1.24.1.2.1.1.7

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: This object indicates the time after which the severity specified by alarmModelState will be escalated to major.

What is cienaCesAlarmToMajor?

This sets how many seconds an alarm must remain active before its severity is escalated to major. Sitting between the minor and critical escalation thresholds for the same alarm model, this value determines how much longer operations staff have before an alarm that already went minor gets treated as a real service-impacting event requiring active response. For example, configured at 120 seconds, an optical-power alarm that has stayed at minor severity for two full minutes automatically becomes major, which typically prompts an on-call page.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.24.1.2.1.1.7
snmpwalk -v2c -c public <target> CIENA-CES-ALARM-MIB::cienaCesAlarmToMajor

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.24.1.2.1.1.7.1
snmpget -v2c -c public <target> CIENA-CES-ALARM-MIB::cienaCesAlarmToMajor.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-ALARM-MIB::cienaCesAlarmToMajor OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.24cienaCesAlarmMIBCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1cienaCesAlarmMIBObjectsCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1.2cienaCesAlarmCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1.2.1cienaCesAlarmTableCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1.2.1.1cienaCesAlarmEntryCIENA-CES-ALARM-MIB
1.3.6.1.4.1.1271.2.1.24.1.2.1.1.7cienaCesAlarmToMajorCIENA-CES-ALARM-MIB