CIENA-CES-8021X-MIB :: cienaCes8021xSuppPeerCertReauthAdminState

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-8021X-MIB › cienaCes8021xSuppPeerCertReauthAdminState

cienaCes8021xSuppPeerCertReauthAdminState

Module: CIENA-CES-8021X-MIB

OID (symbolic): CIENA-CES-8021X-MIB::cienaCes8021xSuppPeerCertReauthAdminState

OID (numeric): 1.3.6.1.4.1.1271.2.1.42.2.2.1.24

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Administratively enables/disables peer certificate reauthentication on this supplicant. Applies to EAP-TLS.

What is cienaCes8021xSuppPeerCertReauthAdminState?

This enables periodic reauthentication of the upstream authenticator's certificate on an ongoing basis during an established EAP-TLS session, rather than validating that certificate only once at the initial handshake and then trusting the session indefinitely. An admin enables this to reduce the exposure window if the upstream server's certificate is revoked or replaced mid-session, since a one-time validation at connection time wouldn't catch a certificate that goes bad sometime after the session was already established. For example, in a long-lived uplink connection that stays authenticated for weeks at a time, enabling this ensures the switch periodically re-checks the peer's certificate rather than continuing to trust a session whose original certificate validation is now weeks stale.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.42.2.2.1.24
snmpwalk -v2c -c public <target> CIENA-CES-8021X-MIB::cienaCes8021xSuppPeerCertReauthAdminState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.42.2.2.1.24.1
snmpget -v2c -c public <target> CIENA-CES-8021X-MIB::cienaCes8021xSuppPeerCertReauthAdminState.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1271.2.1.42.2.2.1.24.1 i <value>

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-8021X-MIB::cienaCes8021xSuppPeerCertReauthAdminState OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.42cienaCes8021xMIBCIENA-CES-8021X-MIB
1.3.6.1.4.1.1271.2.1.42.2cienaCes8021xObjsCIENA-CES-8021X-MIB
1.3.6.1.4.1.1271.2.1.42.2.2cienaCes8021xSuppTableCIENA-CES-8021X-MIB
1.3.6.1.4.1.1271.2.1.42.2.2.1cienaCes8021xSuppEntryCIENA-CES-8021X-MIB
1.3.6.1.4.1.1271.2.1.42.2.2.1.24cienaCes8021xSuppPeerCertReauthAdminStateCIENA-CES-8021X-MIB