CIENA-CES-8021X-MIB :: cienaCes8021xSuppCheckCertificateTimeAdminState

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-8021X-MIB › cienaCes8021xSuppCheckCertificateTimeAdminState

cienaCes8021xSuppCheckCertificateTimeAdminState

Module: CIENA-CES-8021X-MIB

OID (symbolic): CIENA-CES-8021X-MIB::cienaCes8021xSuppCheckCertificateTimeAdminState

OID (numeric): 1.3.6.1.4.1.1271.2.1.42.2.2.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Administratively enables/disables checking of the server's certificate timestamp when doing mutual authentication. Applies to EAP-TLS.

What is cienaCes8021xSuppCheckCertificateTimeAdminState?

This is a specific sub-check within mutual authentication: when enabled, the switch will additionally verify that the upstream server's certificate's validity timestamp is current (not expired or not-yet-valid) as part of confirming that server's identity during EAP-TLS mutual authentication. An admin would enable this for a stricter security posture, catching a case where an otherwise trusted certificate chain has simply expired, which a basic identity check alone might miss. For example, an admin renewing certificate infrastructure would want this enabled so that if the upstream authentication server's certificate is accidentally left unrenewed past its expiry, the switch's own supplicant authentication would fail closed rather than silently accepting an expired cert.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.42.2.2.1.14
snmpwalk -v2c -c public <target> CIENA-CES-8021X-MIB::cienaCes8021xSuppCheckCertificateTimeAdminState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.42.2.2.1.14.1
snmpget -v2c -c public <target> CIENA-CES-8021X-MIB::cienaCes8021xSuppCheckCertificateTimeAdminState.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1271.2.1.42.2.2.1.14.1 i <value>

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-8021X-MIB::cienaCes8021xSuppCheckCertificateTimeAdminState OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.42cienaCes8021xMIBCIENA-CES-8021X-MIB
1.3.6.1.4.1.1271.2.1.42.2cienaCes8021xObjsCIENA-CES-8021X-MIB
1.3.6.1.4.1.1271.2.1.42.2.2cienaCes8021xSuppTableCIENA-CES-8021X-MIB
1.3.6.1.4.1.1271.2.1.42.2.2.1cienaCes8021xSuppEntryCIENA-CES-8021X-MIB
1.3.6.1.4.1.1271.2.1.42.2.2.1.14cienaCes8021xSuppCheckCertificateTimeAdminStateCIENA-CES-8021X-MIB