CDX-6500-COMMON-MIB :: cdx6500PVCSetupSource

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCDX-6500-COMMON-MIBcdx6500PVCSetupSource

cdx6500PVCSetupSource

Module: CDX-6500-COMMON-MIB

OID (symbolic): CDX-6500-COMMON-MIB::cdx6500PVCSetupSource

OID (numeric): 1.3.6.1.4.1.449.2.1.2.2.5.1.2

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: This is the PVC source channel identifier. Entries are not case sensitive. For example: BCST route calls to the broadcast module. MX25-2s3(2) route calls to MX25 port 2, station 3, channel 2. PAD-5 route calls to PAD port 5. P54S9(22) route calls to port 54, station 9, channel 22. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1(5) route calls to X25 port 1, channel 5.

What is cdx6500PVCSetupSource?

This sets the case-insensitive source channel identifier for a permanent virtual circuit, using formats like BCST for broadcast, a port-station-channel combination like MX25-2s3(2), or a plain PAD port reference like PAD-5. An admin configures this as one end of a fixed, always-on circuit through the node, distinct from switched virtual calls which are set up dynamically per route-selection rules elsewhere in this MIB. For example, setting this to 'P54S9(22)' anchors one end of a permanent circuit at port 54, station 9, channel 22.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.2.5.1.2
snmpwalk -v2c -c public <target> CDX-6500-COMMON-MIB::cdx6500PVCSetupSource

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.2.5.1.2.1
snmpget -v2c -c public <target> CDX-6500-COMMON-MIB::cdx6500PVCSetupSource.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.2.5.1.2.1 s <value>

Start monitoring Motorola/Codex CDX 6500 statistical multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDX-6500-COMMON-MIB::cdx6500PVCSetupSource OID value, configure state conditions and alerts, and monitor any Motorola/Codex CDX 6500 statistical multiplexer (legacy) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.2cdx6500CfgGeneralGroupCDX-6500-COMMON-MIB
1.3.6.1.4.1.449.2.1.2.2.5cdx6500GCTPVCSetupTableCDX-6500-COMMON-MIB
1.3.6.1.4.1.449.2.1.2.2.5.1cdx6500GCTPVCSetupEntryCDX-6500-COMMON-MIB
1.3.6.1.4.1.449.2.1.2.2.5.1.2cdx6500PVCSetupSourceCDX-6500-COMMON-MIB