CDM-570 :: cdm570TxPowerLevel

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCDM-570cdm570TxPowerLevel

cdm570TxPowerLevel

Module: CDM-570

OID (symbolic): CDM-570::cdm570TxPowerLevel

OID (numeric): 1.3.6.1.4.1.6247.24.1.2.2.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Transmit output power level for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modem. CDM-570L power level is between -40 and 0 dBm. CDM-570 power level is between -25 and 0 dBm. Units = 0.1 dBm

What is cdm570TxPowerLevel?

This read-write object sets the transmit output power level in 0.1 dBm units, from -400 to 0, i.e., -40 to 0 dBm, with the description noting the CDM-570L variant's usable range is -40 to 0 dBm while the CDM-570 variant's is -25 to 0 dBm. This directly determines the RF power delivered toward the antenna's upconverter/BUC, so it must be set in coordination with the BUC's own gain and the link budget's required EIRP -- set too low and the far end can't achieve adequate Eb/No, set too high and it risks driving the BUC or the transponder into unwanted nonlinearity or interference with adjacent carriers. An admin performing a link budget calculation for a small remote antenna might set this to a modest negative dBm value into a BUC with substantial gain, targeting a specific EIRP the link budget calls for to reach the satellite with adequate margin.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.2.2.10
snmpwalk -v2c -c public <target> CDM-570::cdm570TxPowerLevel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.2.2.10.1
snmpget -v2c -c public <target> CDM-570::cdm570TxPowerLevel.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6247.24.1.2.2.10.1 i <value>

Start monitoring Comtech EF Data satellite modems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDM-570::cdm570TxPowerLevel OID value, configure state conditions and alerts, and monitor any Comtech EF Data satellite modems from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6247comtechEFDataComtechEFData
Numeric OIDNameModule
1.3.6.1.4.1.6247.24cdm570CDM-570
1.3.6.1.4.1.6247.24.1cdm570ObjectsCDM-570
1.3.6.1.4.1.6247.24.1.2cdm570ConfigCDM-570
1.3.6.1.4.1.6247.24.1.2.2cdm570TxCDM-570
1.3.6.1.4.1.6247.24.1.2.2.10cdm570TxPowerLevelCDM-570