All MIBs › CDM-570 › cdm570AlarmMaskEbNoAlarm
cdm570AlarmMaskEbNoAlarm
Module: CDM-570
OID (symbolic): CDM-570::cdm570AlarmMaskEbNoAlarm
OID (numeric): 1.3.6.1.4.1.6247.24.1.2.7.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Eb/No alarm mask, where: 0 = Unmasked 1 = Masked
What is cdm570AlarmMaskEbNoAlarm?
This read-write object masks or unmasks the Eb/No alarm: unmasked(0) or masked(1). This controls whether crossing the threshold configured in cdm570RxEbNoAlarmPoint actually surfaces as a visible alarm, and masking it is a deliberate choice typically made only when Eb/No is already being monitored more precisely through direct polling of cdm570RxEbNo by a higher-level system, making the modem's own threshold alarm redundant. If a higher-level monitoring platform already polls the Eb/No value directly and applies its own custom alerting logic, an admin might mask this onboard alarm to avoid duplicate notifications for the same underlying signal-quality condition.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.2.7.5 snmpwalk -v2c -c public <target> CDM-570::cdm570AlarmMaskEbNoAlarm
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.2.7.5.1 snmpget -v2c -c public <target> CDM-570::cdm570AlarmMaskEbNoAlarm.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6247.24.1.2.7.5.1 i <value>
Start monitoring Comtech EF Data satellite modems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDM-570::cdm570AlarmMaskEbNoAlarm OID value, configure state conditions and alerts, and monitor any Comtech EF Data satellite modems from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6247 | comtechEFData | ComtechEFData |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6247.24 | cdm570 | CDM-570 |
| 1.3.6.1.4.1.6247.24.1 | cdm570Objects | CDM-570 |
| 1.3.6.1.4.1.6247.24.1.2 | cdm570Config | CDM-570 |
| 1.3.6.1.4.1.6247.24.1.2.7 | cdm570AlarmMask | CDM-570 |
| 1.3.6.1.4.1.6247.24.1.2.7.5 | cdm570AlarmMaskEbNoAlarm | CDM-570 |