All MIBs › CDM-570 › cdm570AUPCRemoteDemodEbNo
cdm570AUPCRemoteDemodEbNo
Module: CDM-570
OID (symbolic): CDM-570::cdm570AUPCRemoteDemodEbNo
OID (numeric): 1.3.6.1.4.1.6247.24.1.3.5.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Returns the value of the Eb/No ofthe remote demodulator. Units = 0.1 dB Responds 999 = remote demod unlocked. Responds 0 = EDMAC is disabled.
What is cdm570AUPCRemoteDemodEbNo?
This returns the Eb/No measured by the demodulator at the far end of the link, relayed back over the EDMAC monitoring channel, with 999 meaning the remote demod is unlocked and 0 meaning EDMAC itself is disabled. Because it reflects the remote receiver's actual signal quality rather than this unit's own, it is the value an admin at the local site checks to know whether the far-end link is healthy without separate access to that remote modem. A reading of 999 while the local Eb/No looks fine would point to a problem specific to the remote site, such as antenna misalignment or an LNB failure, rather than anything on this end.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.3.5.1 snmpwalk -v2c -c public <target> CDM-570::cdm570AUPCRemoteDemodEbNo
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.3.5.1.1 snmpget -v2c -c public <target> CDM-570::cdm570AUPCRemoteDemodEbNo.1
Start monitoring Comtech EF Data satellite modems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDM-570::cdm570AUPCRemoteDemodEbNo OID value, configure state conditions and alerts, and monitor any Comtech EF Data satellite modems from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6247 | comtechEFData | ComtechEFData |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6247.24 | cdm570 | CDM-570 |
| 1.3.6.1.4.1.6247.24.1 | cdm570Objects | CDM-570 |
| 1.3.6.1.4.1.6247.24.1.3 | cdm570Monitor | CDM-570 |
| 1.3.6.1.4.1.6247.24.1.3.5 | cdm570AUPCParams | CDM-570 |
| 1.3.6.1.4.1.6247.24.1.3.5.1 | cdm570AUPCRemoteDemodEbNo | CDM-570 |