CAMBIUM-PTP500-MIB :: sNMPPortNumber

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCAMBIUM-PTP500-MIBsNMPPortNumber

sNMPPortNumber

Module: CAMBIUM-PTP500-MIB

OID (symbolic): CAMBIUM-PTP500-MIB::sNMPPortNumber

OID (numeric): 1.3.6.1.4.1.17713.5.16.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The IP port number used to access the SNMP MIB (i.e. Gets and Sets) (default = 161). NB: A system reboot is required to activate changes to this attribute

What is sNMPPortNumber?

Sets the UDP port number used for SNMP access (gets and sets) to this unit, default 161. Requires a reboot to take effect.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17713.5.16.1
snmpwalk -v2c -c public <target> CAMBIUM-PTP500-MIB::sNMPPortNumber

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.17713.5.16.1.1
snmpget -v2c -c public <target> CAMBIUM-PTP500-MIB::sNMPPortNumber.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.17713.5.16.1.1 i <value>

Start monitoring Cambium Networks PTP-series wireless Ethernet bridge with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CAMBIUM-PTP500-MIB::sNMPPortNumber OID value, configure state conditions and alerts, and monitor any Cambium Networks PTP-series wireless Ethernet bridge from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.17713cambiumCAMBIUM-PMP80211-MIB
Numeric OIDNameModule
1.3.6.1.4.1.17713.5ptp500CAMBIUM-PTP500-MIB
1.3.6.1.4.1.17713.5.16snmpControlCAMBIUM-PTP500-MIB
1.3.6.1.4.1.17713.5.16.1sNMPPortNumberCAMBIUM-PTP500-MIB