All MIBs › CAMBIUM-PTP500-MIB › remoteMaximumTransmitPower
remoteMaximumTransmitPower
Module: CAMBIUM-PTP500-MIB
OID (symbolic): CAMBIUM-PTP500-MIB::remoteMaximumTransmitPower
OID (numeric): 1.3.6.1.4.1.17713.5.10.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Maximum transmit power the remote wireless unit is permitted to use when establishing and maintaining the wireless link
What is remoteMaximumTransmitPower?
Reports the maximum transmit power the peer (remote) wireless unit is permitted to use, as opposed to maximumTransmitPower which is the local unit's own limit.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17713.5.10.4 snmpwalk -v2c -c public <target> CAMBIUM-PTP500-MIB::remoteMaximumTransmitPower
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.17713.5.10.4.1 snmpget -v2c -c public <target> CAMBIUM-PTP500-MIB::remoteMaximumTransmitPower.1
Start monitoring Cambium Networks PTP-series wireless Ethernet bridge with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CAMBIUM-PTP500-MIB::remoteMaximumTransmitPower OID value, configure state conditions and alerts, and monitor any Cambium Networks PTP-series wireless Ethernet bridge from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.17713 | cambium | CAMBIUM-PMP80211-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.17713.5 | ptp500 | CAMBIUM-PTP500-MIB |
| 1.3.6.1.4.1.17713.5.10 | phyControl | CAMBIUM-PTP500-MIB |
| 1.3.6.1.4.1.17713.5.10.4 | remoteMaximumTransmitPower | CAMBIUM-PTP500-MIB |