CAIUXSA2-MIB :: uxsA2StatusDirMod

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCAIUXSA2-MIBuxsA2StatusDirMod

uxsA2StatusDirMod

Module: CAIUXSA2-MIB

OID (symbolic): CAIUXSA2-MIB::uxsA2StatusDirMod

OID (numeric): 1.3.6.1.4.1.791.2.10.2.74.2.9.2.1.34

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: &Current monitor condition for the modification monitoring of the directory watcher. As a reference for modification the user can choose between modification time, change time, change time only (change time is modified and modification time is not), and access time. All times can be monitored for being modified (should-be-modified, should-be-changed, should-be-changed-only, should-be-accessed) or for being unmodified (should-not-be-modified, should-not-be-changed, should-not-be-changed-only, should-not-be-accessed). At each poll the latest timestamp of the chosen policy for the directory in question will be compared with the reference timestamp. If the resulting monitor status is 'up' the reference time is set automatically to the most recent value of access time, change time, or modification time. If the monitor status is 'down' the metric may be reset manually by setting the monitor condition to reset-time-reference. Status calculation depends on the kind of monitoring (modified or unmodified) and the value of 'DirModInterval'. If monitoring is for being modified the status is down if the file was not modified for more seconds than the value of 'DirModInterval'. Status is reset to up if there are modifications within 'DirModInterval'. If monitoring is for being unmodified the status is down if the file was modified more often than every 'DirModInterval' seconds. If 'DirModInterval' is zero any modification sets the status down. Note that status evaluation only takes place when the agent polls. Thus the end of the modification interval will be detected on the subsequent poll.

What is uxsA2StatusDirMod?

A configurable setting that determines which timestamp (modification time, change time, change-time-only, or access time) is used as the basis for detecting changes to the monitored directory.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.791.2.10.2.74.2.9.2.1.34
snmpwalk -v2c -c public <target> CAIUXSA2-MIB::uxsA2StatusDirMod

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.791.2.10.2.74.2.9.2.1.34.1
snmpget -v2c -c public <target> CAIUXSA2-MIB::uxsA2StatusDirMod.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.791.2.10.2.74.2.9.2.1.34.1 i <value>

Start monitoring UNIX server managed by CA Unicenter TNG (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CAIUXSA2-MIB::uxsA2StatusDirMod OID value, configure state conditions and alerts, and monitor any UNIX server managed by CA Unicenter TNG (legacy) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.791caiCA-NTOS-MIB
1.3.6.1.4.1.791.2caiSysMgrCA-NTOS-MIB
1.3.6.1.4.1.791.2.10tngCA-W2KOS-MIB
1.3.6.1.4.1.791.2.10.2agentsCA-W2KOS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.791.2.10.2.74caiUxsA2CAIUXSA2-MIB
1.3.6.1.4.1.791.2.10.2.74.2uxsA2StatusGroupCAIUXSA2-MIB
1.3.6.1.4.1.791.2.10.2.74.2.9uxsA2StatusDirGroupCAIUXSA2-MIB
1.3.6.1.4.1.791.2.10.2.74.2.9.2uxsA2StatusDirTableCAIUXSA2-MIB
1.3.6.1.4.1.791.2.10.2.74.2.9.2.1uxsA2StatusDirEntryCAIUXSA2-MIB
1.3.6.1.4.1.791.2.10.2.74.2.9.2.1.34uxsA2StatusDirModCAIUXSA2-MIB