CADANT-CMTS-DOWNCHANNEL-MIB :: cadDownChannelMinFrequency

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCADANT-CMTS-DOWNCHANNEL-MIBcadDownChannelMinFrequency

cadDownChannelMinFrequency

Module: CADANT-CMTS-DOWNCHANNEL-MIB

OID (symbolic): CADANT-CMTS-DOWNCHANNEL-MIB::cadDownChannelMinFrequency

OID (numeric): 1.3.6.1.4.1.4998.1.1.15.2.2.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object is used to configure the C4 CMTS to accept minimum downstream frequency limit that conform with the EuroDOCSIS specifications (starndard range 112 MHz to 858 MHz), (extended 85 MHz to 999MHz) or to the DOCSIS specifications (standard 91 to 867 MHz), (extended range 57 MHz to 999 MHz). Changes to downstream frequency and width are verified against this object to ensure the C4 CMTS does not exceed the downstream spectrum limits imposed by this object. Attempting to increase the minimum downstream frequency limit implied by this object will fail if at least a single downstream is configured outside of the range for the new value. It is recommended this object be set during initial system setup.

What is cadDownChannelMinFrequency?

Configures the lower bound of the acceptable downstream frequency range, ensuring assigned channels conform to the chosen DOCSIS or EuroDOCSIS frequency plan. Channels assigned below this limit will be rejected by the CMTS.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.15.2.2.2
snmpwalk -v2c -c public <target> CADANT-CMTS-DOWNCHANNEL-MIB::cadDownChannelMinFrequency

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.15.2.2.2.1
snmpget -v2c -c public <target> CADANT-CMTS-DOWNCHANNEL-MIB::cadDownChannelMinFrequency.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4998.1.1.15.2.2.2.1 i <value>

Start monitoring ARRIS/Cadant C4/E6000 CMTS (cable modem termination system) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CADANT-CMTS-DOWNCHANNEL-MIB::cadDownChannelMinFrequency OID value, configure state conditions and alerts, and monitor any ARRIS/Cadant C4/E6000 CMTS (cable modem termination system) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4998cadantCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1cadObjectsCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1cadCableCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1.15cadSpectrumCADANT-PRODUCTS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4998.1.1.15.2cadDownchannelMibCADANT-CMTS-DOWNCHANNEL-MIB
1.3.6.1.4.1.4998.1.1.15.2.2cadDownChannelParamsCADANT-CMTS-DOWNCHANNEL-MIB