BW-BroadworksMediaServer :: msNoPortAvailableErrors

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBW-BroadworksMediaServermsNoPortAvailableErrors

msNoPortAvailableErrors

Module: BW-BroadworksMediaServer

OID (symbolic): BW-BroadworksMediaServer::msNoPortAvailableErrors

OID (numeric): 1.3.6.1.4.1.6431.1.3.1.6

Node type: OBJECT-TYPE

Type: Counter64

Access: read-write

Description: Number of 'no ports available' errors

What is msNoPortAvailableErrors?

Counts how many times a request for a media port failed because no port was free at the time. A climbing count is a sign the server is undersized for its call load or is nearing its licensed port limit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6431.1.3.1.6
snmpwalk -v2c -c public <target> BW-BroadworksMediaServer::msNoPortAvailableErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6431.1.3.1.6.1
snmpget -v2c -c public <target> BW-BroadworksMediaServer::msNoPortAvailableErrors.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6431.1.3.1.6.1 i <value>

Start monitoring BroadSoft BroadWorks VoIP/UC application servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BW-BroadworksMediaServer::msNoPortAvailableErrors OID value, configure state conditions and alerts, and monitor any BroadSoft BroadWorks VoIP/UC application servers from a single console.

How to Use in IPNetwork Monitor

Select a BroadSoft BroadWorks VoIP/UC application server as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type msNoPortAvailableErrors into the Find box to locate it in the OID tree, then select it and click OK. It reports the number of 'no ports available' errors. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6431broadsoftBroadworksFault
1.3.6.1.4.1.6431.1broadworksBroadworksFault
Numeric OIDNameModule
1.3.6.1.4.1.6431.1.3mediaServerBW-BroadworksMediaServer
1.3.6.1.4.1.6431.1.3.1mcpBW-BroadworksMediaServer
1.3.6.1.4.1.6431.1.3.1.6msNoPortAvailableErrorsBW-BroadworksMediaServer