BSTD-OPT-MIB :: cdx6500BSTDCfgResponseTimeout

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBSTD-OPT-MIBcdx6500BSTDCfgResponseTimeout

cdx6500BSTDCfgResponseTimeout

Module: BSTD-OPT-MIB

OID (symbolic): BSTD-OPT-MIB::cdx6500BSTDCfgResponseTimeout

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.14.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Specifies the amount of time in msec the PAD allows a terminal, printer or host to respond. As a result, the TPAD may re-transmit the previous message or abort the current procedure. The HPAD aborts the current procedure as though EOT was received, allowing this HPAD station to disconnect it's X.25 circuit if the host malfunctions. An HPAD with a response timeout shorter than the hosts ability to respond may result in Inbound Errors.

What is cdx6500BSTDCfgResponseTimeout?

This read-only value (400-5000 msec) sets how long the PAD waits for a terminal, printer, or host to respond before the TPAD re-transmits the message or the HPAD aborts the procedure as if an EOT was received. Setting this too short relative to how slowly the host actually responds can cause spurious Inbound Errors.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.14.1.11
snmpwalk -v2c -c public <target> BSTD-OPT-MIB::cdx6500BSTDCfgResponseTimeout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.14.1.11.1
snmpget -v2c -c public <target> BSTD-OPT-MIB::cdx6500BSTDCfgResponseTimeout.1

Start monitoring Motorola Codex 6500-series data/statistical multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BSTD-OPT-MIB::cdx6500BSTDCfgResponseTimeout OID value, configure state conditions and alerts, and monitor any Motorola Codex 6500-series data/statistical multiplexer (legacy) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1cdx6500PCTPortProtocolGroupALC-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.1.14cdx6500PPCTBSTDPortTableBSTD-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.14.1cdx6500PPCTBSTDPortEntryBSTD-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.14.1.11cdx6500BSTDCfgResponseTimeoutBSTD-OPT-MIB