BSC3270-OPT-MIB :: cdx6500BSC3270PortOptions

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBSC3270-OPT-MIBcdx6500BSC3270PortOptions

cdx6500BSC3270PortOptions

Module: BSC3270-OPT-MIB

OID (symbolic): BSC3270-OPT-MIB::cdx6500BSC3270PortOptions

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.10.1.18

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: Select options on this BSC3270 port as follows: NONE - no option specified CESS - Turn the polling cessation option ON. In the HPAD, a G-POLL will not be responded to if none of the terminals configured on that controller are in a connected state (ie. no SVC in place) and there are no printers configured on that controller. A S-POLL or SELECT or a data message to a terminal will not be responded to if that device is not in a connected state. In the TPAD, devices that are configured for AUTO+ORG will be polled only once per service timer interval until the connection (SVC) to the remote HPAD is established. SINGLE - Turn single message delivery option ON. The Hpad will transmit only one complete message (single or multiple block message) when responding to a Specific or a General Poll. This option applies only to Hpad ports. Any combination of above specified by summing (eg. CESS+SINGLE).

What is cdx6500BSC3270PortOptions?

This read-only object lists which options are turned on for the port, such as CESS (skip responding to certain polls/selects when no device is connected) and SINGLE (Hpad delivers only one complete message per poll response); multiple options can be combined by summing their values.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.10.1.18
snmpwalk -v2c -c public <target> BSC3270-OPT-MIB::cdx6500BSC3270PortOptions

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.10.1.18.1
snmpget -v2c -c public <target> BSC3270-OPT-MIB::cdx6500BSC3270PortOptions.1

Start monitoring Motorola Codex 6500-series data/statistical multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BSC3270-OPT-MIB::cdx6500BSC3270PortOptions OID value, configure state conditions and alerts, and monitor any Motorola Codex 6500-series data/statistical multiplexer (legacy) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1cdx6500PCTPortProtocolGroupALC-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.1.10cdx6500PPCTBSC3270PortTableBSC3270-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.10.1cdx6500PPCTBSC3270PortEntryBSC3270-OPT-MIB