All MIBs › BRIDGE-OPT-MIB › cdx6500LfcmStaticOutProtLinkAct
cdx6500LfcmStaticOutProtLinkAct
Module: BRIDGE-OPT-MIB
OID (symbolic): BRIDGE-OPT-MIB::cdx6500LfcmStaticOutProtLinkAct
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.6.2.1.5
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: PASS = Pass all. If this value is used, outgoing frames with the specified protocol value will be passed on all links. All other protocols will be blocked on outgoing links. (See User's Manual). BLOCK = Block all. If this value is used, outgoing frames with the specified protocol value will be blocked on all links. All other protocols will be passed on outgoing links. (See User's Manual). PASSLIST = Pass List. Links in this list will pass the frame. Links not in this list will block the frame. An empty list means all links will block. (See User's Manual). BLOCKLIST = Block List. Links in this list will block the frame. Links not in this list will pass the frame. An empty list will mean all links will pass. (See User's Manual).
What is cdx6500LfcmStaticOutProtLinkAct?
This read-write field controls how outgoing frames carrying this row's protocol value are treated: PASS or BLOCK them on all links (with the opposite action applied to every other protocol), or use PASSLIST/BLOCKLIST to apply the per-link list in the companion OutProtList object. It's the outbound counterpart to cdx6500LfcmStaticIncProtLinkAct.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.6.2.1.5 snmpwalk -v2c -c public <target> BRIDGE-OPT-MIB::cdx6500LfcmStaticOutProtLinkAct
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.6.2.1.5.1 snmpget -v2c -c public <target> BRIDGE-OPT-MIB::cdx6500LfcmStaticOutProtLinkAct.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.6.2.1.5.1 s <value>
Start monitoring Motorola Codex 6500-series data/statistical multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BRIDGE-OPT-MIB::cdx6500LfcmStaticOutProtLinkAct OID value, configure state conditions and alerts, and monitor any Motorola Codex 6500-series data/statistical multiplexer (legacy) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449.2.1.2.1.6 | cdx6500PCTBridgeGroup | BRIDGE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.6.2 | cdx6500PCTPortStaticProtTable | BRIDGE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.6.2.1 | cdx6500PCTPortStaticProtEntry | BRIDGE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.6.2.1.5 | cdx6500LfcmStaticOutProtLinkAct | BRIDGE-OPT-MIB |