All MIBs › BRIDGE-OPT-MIB › cdx6500LfcmStaticIncProtLinkAct
cdx6500LfcmStaticIncProtLinkAct
Module: BRIDGE-OPT-MIB
OID (symbolic): BRIDGE-OPT-MIB::cdx6500LfcmStaticIncProtLinkAct
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.6.2.1.4
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: PASS = Pass all. If this value is used, incoming frames with the specified protocol value will be passed on all links. All other protocols will be blocked on incoming links. (See User's Manual). BLOCK = Block all. If this value is used, incoming frames with the specified protocol value will be blocked on all links. All other protocols will be passed on incoming links. (See User's Manual). PASSLIST = Pass List. Links in the list will pass the frame. Links not in this list will block the frame. An empty list means all links will block. (See User's Manual). BLOCKLIST = Block List. Links in the list will block the frame. Links not in this list will pass the frame. An empty list will mean all links will pass. (See User's Manual).
What is cdx6500LfcmStaticIncProtLinkAct?
This read-write field controls how incoming frames carrying this row's protocol value are treated: PASS or BLOCK them on all links (with the opposite action applied to every other protocol), or use PASSLIST/BLOCKLIST to apply the per-link list in the companion IncProtList object. An empty PASSLIST blocks the protocol on all links, while an empty BLOCKLIST passes it everywhere.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.6.2.1.4 snmpwalk -v2c -c public <target> BRIDGE-OPT-MIB::cdx6500LfcmStaticIncProtLinkAct
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.6.2.1.4.1 snmpget -v2c -c public <target> BRIDGE-OPT-MIB::cdx6500LfcmStaticIncProtLinkAct.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.6.2.1.4.1 s <value>
Start monitoring Motorola Codex 6500-series data/statistical multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BRIDGE-OPT-MIB::cdx6500LfcmStaticIncProtLinkAct OID value, configure state conditions and alerts, and monitor any Motorola Codex 6500-series data/statistical multiplexer (legacy) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449.2.1.2.1.6 | cdx6500PCTBridgeGroup | BRIDGE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.6.2 | cdx6500PCTPortStaticProtTable | BRIDGE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.6.2.1 | cdx6500PCTPortStaticProtEntry | BRIDGE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.6.2.1.4 | cdx6500LfcmStaticIncProtLinkAct | BRIDGE-OPT-MIB |