All MIBs › BRI-OPT-MIB › cdx6500BRIX25ChanCfgNumPVCChannels
cdx6500BRIX25ChanCfgNumPVCChannels
Module: BRI-OPT-MIB
OID (symbolic): BRI-OPT-MIB::cdx6500BRIX25ChanCfgNumPVCChannels
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.13
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table.
What is cdx6500BRIX25ChanCfgNumPVCChannels?
The number of logical channels reserved on this link for Permanent Virtual Circuits (PVCs). The description warns the combined total of PVC and SVC channels on a link should be kept as small as actually needed, and that PVC connections still have to be configured separately in the PVC table.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.13 snmpwalk -v2c -c public <target> BRI-OPT-MIB::cdx6500BRIX25ChanCfgNumPVCChannels
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.13.1 snmpget -v2c -c public <target> BRI-OPT-MIB::cdx6500BRIX25ChanCfgNumPVCChannels.1
Start monitoring Motorola Codex 6500-series data/statistical multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BRI-OPT-MIB::cdx6500BRIX25ChanCfgNumPVCChannels OID value, configure state conditions and alerts, and monitor any Motorola Codex 6500-series data/statistical multiplexer (legacy) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1 | cdx6500PCTPortProtocolGroup | ALC-OPT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449.2.1.2.1.1.26 | cdx6500PPCTISDN | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1 | cdx6500PPCTBRIConfig | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2 | cdx6500PPCTBRIChan | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1 | cdx6500PPCTBRIX25ChanTable | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1 | cdx6500PPCTBRIX25ChanEntry | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.13 | cdx6500BRIX25ChanCfgNumPVCChannels | BRI-OPT-MIB |