BRI-OPT-MIB :: cdx6500BRIX25ChanCfgFacToBarInOutbCalls

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBRI-OPT-MIBcdx6500BRIX25ChanCfgFacToBarInOutbCalls

cdx6500BRIX25ChanCfgFacToBarInOutbCalls

Module: BRI-OPT-MIB

OID (symbolic): BRI-OPT-MIB::cdx6500BRIX25ChanCfgFacToBarInOutbCalls

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.35

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: Specify facilities which, if present in an outbound call, will be blocked by the port: NONE - no facility blocked REV - bar reverse charging FAST - bar fast select BCUG - bar Bilateral Closed User Group DGRAM - bar datagram Any combination of above specified by summing (e.g. REV+FAST).

What is cdx6500BRIX25ChanCfgFacToBarInOutbCalls?

Lists X.25 facilities that, if present in an outbound call, will cause the port to block the call outright -- e.g. REV (reverse charging), FAST (fast select), BCUG, or DGRAM (datagram); combinations are summed together, e.g. REV+FAST.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.35
snmpwalk -v2c -c public <target> BRI-OPT-MIB::cdx6500BRIX25ChanCfgFacToBarInOutbCalls

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.35.1
snmpget -v2c -c public <target> BRI-OPT-MIB::cdx6500BRIX25ChanCfgFacToBarInOutbCalls.1

Start monitoring Motorola Codex 6500-series data/statistical multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BRI-OPT-MIB::cdx6500BRIX25ChanCfgFacToBarInOutbCalls OID value, configure state conditions and alerts, and monitor any Motorola Codex 6500-series data/statistical multiplexer (legacy) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1cdx6500PCTPortProtocolGroupALC-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.1.26cdx6500PPCTISDNBRI-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.26.1cdx6500PPCTBRIConfigBRI-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.26.1.2cdx6500PPCTBRIChanBRI-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1cdx6500PPCTBRIX25ChanTableBRI-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1cdx6500PPCTBRIX25ChanEntryBRI-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.35cdx6500BRIX25ChanCfgFacToBarInOutbCallsBRI-OPT-MIB