All MIBs › BRI-OPT-MIB › cdx6500BRIX25ChanCfgFacToAddToOutbCalls
cdx6500BRIX25ChanCfgFacToAddToOutbCalls
Module: BRI-OPT-MIB
OID (symbolic): BRI-OPT-MIB::cdx6500BRIX25ChanCfgFacToAddToOutbCalls
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.34
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: Specify facilities added to an outbound call before it is forwarded: NONE - no facilities added REV - add reverse charging PACK - add packet size negotiation WIND - add window size negotiation Any combination of above specified by summing (e.g. PACK+WIND+. . .).
What is cdx6500BRIX25ChanCfgFacToAddToOutbCalls?
Lists which X.25 facilities are added to an outbound call before it is forwarded, such as REV (reverse charging), PACK (packet size negotiation), or WIND (window size negotiation); codes can be combined, e.g. PACK+WIND.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.34 snmpwalk -v2c -c public <target> BRI-OPT-MIB::cdx6500BRIX25ChanCfgFacToAddToOutbCalls
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.34.1 snmpget -v2c -c public <target> BRI-OPT-MIB::cdx6500BRIX25ChanCfgFacToAddToOutbCalls.1
Start monitoring Motorola Codex 6500-series data/statistical multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BRI-OPT-MIB::cdx6500BRIX25ChanCfgFacToAddToOutbCalls OID value, configure state conditions and alerts, and monitor any Motorola Codex 6500-series data/statistical multiplexer (legacy) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1 | cdx6500PCTPortProtocolGroup | ALC-OPT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449.2.1.2.1.1.26 | cdx6500PPCTISDN | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1 | cdx6500PPCTBRIConfig | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2 | cdx6500PPCTBRIChan | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1 | cdx6500PPCTBRIX25ChanTable | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1 | cdx6500PPCTBRIX25ChanEntry | BRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.26.1.2.1.1.34 | cdx6500BRIX25ChanCfgFacToAddToOutbCalls | BRI-OPT-MIB |