Description: Indicates whether a second warning for low battery power has been issued.
secondWarning(1) - a second warning has been issued. noSecondWarning(2) - no second warning has been issued.
This object is now obsolete.
What is raidControllerBatteryBackupSecondWarning?
This obsolete field indicated whether a second, more urgent low-battery-power warning had been issued for the battery backup unit, following on from the first warning stage tracked separately.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.3.2.1.3.1.5 snmpwalk -v2c -c public <target> BLUEARC-SERVER-MIB::raidControllerBatteryBackupSecondWarning
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.3.2.1.3.1.5.1 snmpget -v2c -c public <target> BLUEARC-SERVER-MIB::raidControllerBatteryBackupSecondWarning.1
Start monitoring BlueArc (Hitachi Data Systems) NAS storage servers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLUEARC-SERVER-MIB::raidControllerBatteryBackupSecondWarning OID value, configure state conditions and alerts, and monitor any BlueArc (Hitachi Data Systems) NAS storage servers (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11096 | blueArc | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6 | blueArcPrivate | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1 | blueArcServer | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1 | blueArcServerObjs | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1 | sys | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.3 | storage | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.3.2 | raid | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.3.2.1 | controllers | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.3.2.1.3 | raidControllerBatteryBackupTable | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.3.2.1.3.1 | raidControllerBatteryBackupEntry | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.3.2.1.3.1.5 | raidControllerBatteryBackupSecondWarning | BLUEARC-SERVER-MIB |