BLUEARC-SERVER-MIB :: puStatsLineMininumVoltage

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBLUEARC-SERVER-MIBpuStatsLineMininumVoltage

puStatsLineMininumVoltage

Module: BLUEARC-SERVER-MIB

OID (symbolic): BLUEARC-SERVER-MIB::puStatsLineMininumVoltage

OID (numeric): 1.3.6.1.4.1.11096.6.1.1.1.1.6.1.10

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The minimum line voltage in Volts.

This object is obsolete. Power units must be indexed by IP address.

What is puStatsLineMininumVoltage?

The minimum AC line voltage recorded by the power unit, in Volts. This object is obsolete, replaced by puStatisticsLineMininumVoltage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.1.6.1.10
snmpwalk -v2c -c public <target> BLUEARC-SERVER-MIB::puStatsLineMininumVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.1.6.1.10.1
snmpget -v2c -c public <target> BLUEARC-SERVER-MIB::puStatsLineMininumVoltage.1

Start monitoring BlueArc (Hitachi Data Systems) NAS storage servers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLUEARC-SERVER-MIB::puStatsLineMininumVoltage OID value, configure state conditions and alerts, and monitor any BlueArc (Hitachi Data Systems) NAS storage servers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11096blueArcBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6blueArcPrivateBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1blueArcServerBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1blueArcServerObjsBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1sysBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1powerUnitsBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1.6puStatsTableBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1.6.1puStatsEntryBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1.6.1.10puStatsLineMininumVoltageBLUEARC-SERVER-MIB