BLUEARC-SERVER-MIB :: puConfigurationShutdownOnLowBattery

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBLUEARC-SERVER-MIBpuConfigurationShutdownOnLowBattery

puConfigurationShutdownOnLowBattery

Module: BLUEARC-SERVER-MIB

OID (symbolic): BLUEARC-SERVER-MIB::puConfigurationShutdownOnLowBattery

OID (numeric): 1.3.6.1.4.1.11096.6.1.1.1.1.8.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: If the value is not -1, then the system will shut down when UPS reports a low battery, with a delay of the specified number of minutes.

What is puConfigurationShutdownOnLowBattery?

The delay, in minutes, after the UPS reports a low-battery condition before the system shuts down; -1 disables this trigger. It's the third of the shutdown triggers alongside puConfigurationShutdownOnBattery and puConfigurationShutdownOnRuntime.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.1.8.1.6
snmpwalk -v2c -c public <target> BLUEARC-SERVER-MIB::puConfigurationShutdownOnLowBattery

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.1.8.1.6.1
snmpget -v2c -c public <target> BLUEARC-SERVER-MIB::puConfigurationShutdownOnLowBattery.1

Start monitoring BlueArc (Hitachi Data Systems) NAS storage servers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLUEARC-SERVER-MIB::puConfigurationShutdownOnLowBattery OID value, configure state conditions and alerts, and monitor any BlueArc (Hitachi Data Systems) NAS storage servers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11096blueArcBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6blueArcPrivateBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1blueArcServerBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1blueArcServerObjsBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1sysBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1powerUnitsBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1.8puConfigurationTableBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1.8.1puConfigurationEntryBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1.8.1.6puConfigurationShutdownOnLowBatteryBLUEARC-SERVER-MIB