BLUEARC-SERVER-MIB :: puConfigShutdownInterval

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBLUEARC-SERVER-MIBpuConfigShutdownInterval

puConfigShutdownInterval

Module: BLUEARC-SERVER-MIB

OID (symbolic): BLUEARC-SERVER-MIB::puConfigShutdownInterval

OID (numeric): 1.3.6.1.4.1.11096.6.1.1.1.1.2.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This variable is used in conjunction with puConfigShutdownRemainingLife such that when either condition is met a controlled shutdown will take place.

puConfigShutdownInterval specifies the interval after which a controlled shutdown should take place in the event of a power outage.

remainingLife(1) - indicates that the shutdown is based on the remaining battery life only and NOT the duration of the power outage. The variable puConfigShutdownRemainingLife determines how the shutdown is controlled. immediately(2) - the shutdown should take place as soon as the power outage is detected. The variable puConfigRemainingLife is irrelevant in this case. oneMinute(3), twoMinutes(4), threeMinutes(5), - the interval after which a controlled fiveMinutes(6), shutdown should take place in the event of tenMinutes(7) a power outage.

NOTE: the variable puConfigShutdownEnabled must be enabled(1), for this variable to have any effect in determining when the controlled shutdown is performed.

This object is obsolete. Power units must be indexed by IP address.

What is puConfigShutdownInterval?

Specifies how long to wait after a power outage before performing a controlled shutdown: immediately, after a fixed number of minutes, or based purely on remaining battery life. This setting only takes effect when puConfigShutdownEnabled is enabled, and the object itself is obsolete, replaced by the newer puConfigurationShutdownOnBattery and puConfigurationShutdownOnRuntime settings.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.1.2.1.3
snmpwalk -v2c -c public <target> BLUEARC-SERVER-MIB::puConfigShutdownInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.1.2.1.3.1
snmpget -v2c -c public <target> BLUEARC-SERVER-MIB::puConfigShutdownInterval.1

Start monitoring BlueArc (Hitachi Data Systems) NAS storage servers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLUEARC-SERVER-MIB::puConfigShutdownInterval OID value, configure state conditions and alerts, and monitor any BlueArc (Hitachi Data Systems) NAS storage servers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11096blueArcBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6blueArcPrivateBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1blueArcServerBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1blueArcServerObjsBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1sysBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1powerUnitsBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1.2puConfigTableBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1.2.1puConfigEntryBLUEARC-SERVER-MIB
1.3.6.1.4.1.11096.6.1.1.1.1.2.1.3puConfigShutdownIntervalBLUEARC-SERVER-MIB