All MIBs › BLUEARC-SERVER-MIB › puConfigShutdownEnabled
puConfigShutdownEnabled
Module: BLUEARC-SERVER-MIB
OID (symbolic): BLUEARC-SERVER-MIB::puConfigShutdownEnabled
OID (numeric): 1.3.6.1.4.1.11096.6.1.1.1.1.2.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Indicates whether the power unit is to control the shutdown of the system when a power outage is detected.
enabled(1) - the power unit will control the shutdown. disabled(2) - the power unit will NOT control the shutdown.
This object is obsolete. Power units must be indexed by IP address.
What is puConfigShutdownEnabled?
Indicates whether the power unit is allowed to trigger a controlled system shutdown when it detects a power outage. This object is obsolete, superseded by puConfigurationMonitoringEnabled.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.1.2.1.2 snmpwalk -v2c -c public <target> BLUEARC-SERVER-MIB::puConfigShutdownEnabled
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11096.6.1.1.1.1.2.1.2.1 snmpget -v2c -c public <target> BLUEARC-SERVER-MIB::puConfigShutdownEnabled.1
Start monitoring BlueArc (Hitachi Data Systems) NAS storage servers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLUEARC-SERVER-MIB::puConfigShutdownEnabled OID value, configure state conditions and alerts, and monitor any BlueArc (Hitachi Data Systems) NAS storage servers (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11096 | blueArc | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6 | blueArcPrivate | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1 | blueArcServer | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1 | blueArcServerObjs | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1 | sys | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.1 | powerUnits | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.1.2 | puConfigTable | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.1.2.1 | puConfigEntry | BLUEARC-SERVER-MIB |
| 1.3.6.1.4.1.11096.6.1.1.1.1.2.1.2 | puConfigShutdownEnabled | BLUEARC-SERVER-MIB |