| OID symbolic | OID numeric | Type | Access | Description |
| bibo | 1.3.6.1.4.1.272.4 | | | |
| bintec | 1.3.6.1.4.1.272 | | | |
| capi | 1.3.6.1.4.1.272.4.7 | | | |
| INT capiApplByteOrder | 1.3.6.1.4.1.272.4.7.1.1.3 | INTEGER | read-only | The byte order used by the application. |
| capiApplEntry | 1.3.6.1.4.1.272.4.7.1.1 | | not-accessible | |
| STR capiApplInfoStr | 1.3.6.1.4.1.272.4.7.1.1.8 | DisplayString | read-only | Information string of CAPI instance: IP address and TCP port
of connecting system and user name if any. |
| INT capiApplNumber | 1.3.6.1.4.1.272.4.7.1.1.1 | INTEGER | read-only | Identification number of the registered application. |
| INT capiApplRegDblkCnt | 1.3.6.1.4.1.272.4.7.1.1.6 | INTEGER | read-only | CAPI_REGISTER: The number of registered B3 data
blocks this application accepts. |
| INT capiApplRegDblkSize | 1.3.6.1.4.1.272.4.7.1.1.7 | INTEGER | read-only | CAPI_REGISTER: The size of registered B3 data
blocks this application accepts. |
| INT capiApplRegLevel3Cnt | 1.3.6.1.4.1.272.4.7.1.1.4 | INTEGER | read-only | CAPI_REGISTER: The number of level 3 connections
this application accepts. |
| INT capiApplRegMsgCnt | 1.3.6.1.4.1.272.4.7.1.1.5 | INTEGER | read-only | CAPI_REGISTER: The number of registered CAPI
messages this application accepts. |
| capiApplTable | 1.3.6.1.4.1.272.4.7.1 | | not-accessible | The capiApplTable contains information for all currently
registered CAPI 1.1 and CAPI 2.0 applications, and their
respective CAPI_REGISTER information.
Creating entries: Entries are created automatically by
the system. After receiving an appropriate
CAPI_REGISTER call, the system 'registers' the
application, and assigns it a unique capiApplNumber.
Deleting entries: Once an application releases, entries
are automatically removed by the system. |
| INT capiApplVersion | 1.3.6.1.4.1.272.4.7.1.1.2 | INTEGER | read-only | The version number of the registered application. |
| capiConfigEntry | 1.3.6.1.4.1.272.4.7.6.1 | | not-accessible | |
| INT capiConfigFax12000 | 1.3.6.1.4.1.272.4.7.6.1.10 | INTEGER | read-write | Enable or disable the 12000Bps Mode for fax transmission.
A lot of fax receivers have problems with this tranmission
mode. Default value is off |
| INT capiConfigFaxG3ECM | 1.3.6.1.4.1.272.4.7.6.1.3 | INTEGER | read-write | Specifies whether ECM (error correction mode)
should be used for G3 facsimile transmissions. |
| INT capiConfigFaxG3RcvSpeed | 1.3.6.1.4.1.272.4.7.6.1.2 | INTEGER | read-write | The G3 facsimile receive speed. For CM-EBRI this
should be set to maximum.
Set this field to `delete' to remove this entry.
The entry can be deleted only if there is no entry
with it's capiConfigStkNumber in the isdnStkTable. |
| INT capiConfigFaxModulation | 1.3.6.1.4.1.272.4.7.6.1.9 | INTEGER | read-write | Set the default transmission protocol for fax.
- v17 max. 14400 Bps new standard
- v33 max. 14000 Bps early standard
- v29 max. 9600 Bps fax standard
- v17s v17 with Swiss capability
- v33s v33 with Swiss capability |
| INT capiConfigFaxTXLevel | 1.3.6.1.4.1.272.4.7.6.1.11 | INTEGER | read-write | Set the transmit level to -x dB db0 = 0dB, db3 = -3dB.
In Germany -6dB (db6) is normally used for facsimile
transmission. |
| INT capiConfigModemDefault | 1.3.6.1.4.1.272.4.7.6.1.8 | INTEGER | read-write | Specifies the modem profile of the mdmProfileTable
which contains the default modem parameters to use
for modem connections. |
| INT capiConfigSendAlerting | 1.3.6.1.4.1.272.4.7.6.1.6 | INTEGER | read-write | For CAPI 1.1 this specifies when the CAPI server
should send alert messages for incoming calls. |
| INT capiConfigStkNumber | 1.3.6.1.4.1.272.4.7.6.1.1 | INTEGER | read-only | The isdnStkNumber this configuration belongs to. |
| capiConfigTable | 1.3.6.1.4.1.272.4.7.6 | | not-accessible | The capiConfigTable contains configuration information
for each ISDN stack. Setting these fields is optional, and
is not required.
Creating entries: Entries are created automatically by
the system when a new ISDN stack is initialised in the
isdnStkTable.
Deleting entries: An entry can be removed by assigning
the value `delete' to its capiConfigFaxG3RcvSpeed object.
It can be removed only if there is no entry with it's
capiConfigStkNumber in the isdnStkTable. |
| INT capiConfigV42bis | 1.3.6.1.4.1.272.4.7.6.1.7 | INTEGER | read-write | Specifies whether V.42bis data compression should be
used. If data compression is activated here,the receiving
or sending side is first queried whether it supports data
compression. The BRICK supports V.42bis data
compression using up to 2 B-channels. |
| INT capiConfigVoiceCoding | 1.3.6.1.4.1.272.4.7.6.1.5 | INTEGER | read-write | Switches the bit order for voice-data. |
| INT capiControllerNumber | 1.3.6.1.4.1.272.4.7.7.1.1 | INTEGER | read-write | The controller number requested by the CAPI application. |
| BIT capiControllerStkMask | 1.3.6.1.4.1.272.4.7.7.1.2 | BitValue | read-write | This binary number defines the ISDN stack(s) to use for
the specified CAPI 1.1 or CAPI 2.0 applications.
For example; `Number=1 StkMask=0b1111 Version=capi20' means:
allow CAPI 2.0 applications requesting ISDN controller 1 to
use the ISDN stacks with IsdnStkNumber 0 - 3 on the BRICK. |
| INT capiControllerVersion | 1.3.6.1.4.1.272.4.7.7.1.3 | INTEGER | read-write | Specifies which CAPI applications (CAPI version 1.1, or 2.0)
this entry applies to.
Set this field to `delete' to delete this entry. |
| INT capiInfoApplication | 1.3.6.1.4.1.272.4.7.5.1.1 | INTEGER | read-only | The application number (capiApplNumber). |
| INT capiInfoC1Command | 1.3.6.1.4.1.272.4.7.5.1.4 | INTEGER | read-only | The CAPI 1.1 command where the info occurred. |
| INT capiInfoC2Command | 1.3.6.1.4.1.272.4.7.5.1.5 | INTEGER | read-only | The CAPI 2.0 command where the info occurred. |
| capiInfoEntry | 1.3.6.1.4.1.272.4.7.5.1 | | not-accessible | |
| HEX capiInfoNcci | 1.3.6.1.4.1.272.4.7.5.1.3 | HexValue | read-only | The NCCI number (capiNcciNumber). |
| HEX capiInfoNumber | 1.3.6.1.4.1.272.4.7.5.1.7 | HexValue | read-only | The info value as specified in the CAPI 1.1/2.0
specification. See Appendix A for a listing of
CAPI 1.1 and CAPI 2.0 info values. |
| HEX capiInfoPlci | 1.3.6.1.4.1.272.4.7.5.1.2 | HexValue | read-only | The CAPI PLCI number (capiPlciNumber). |
| INT capiInfoSubCommand | 1.3.6.1.4.1.272.4.7.5.1.6 | INTEGER | read-only | The CAPI 1.1/2.0 subcommand. |
| capiInfoTable | 1.3.6.1.4.1.272.4.7.5 | | not-accessible | The capiInfoTable contains the last 10 CAPI info codes
and their message identifiers for where the error occured.
The most recent message is at inx 09 with older messages
rolling off the top of the table, i.e. inx 00.
Creating entries: Entries are created automatically by
the system once a CAPI info code is received by a
registered application.
Deleting entries: Entries are removed automatically
by the system. |
| INT capiListenApplication | 1.3.6.1.4.1.272.4.7.2.1.1 | INTEGER | read-only | The application-number (capiApplNumber). |
| HEX capiListenCipMask | 1.3.6.1.4.1.272.4.7.2.1.6 | HexValue | read-only | The bit mask of CAPI 2.0 listen CIPMask. The purpose
of the CIPMask parameter is to select basic classes of
incoming calls. CAPI 2.0 applications only. |
| HEX capiListenCipMask2 | 1.3.6.1.4.1.272.4.7.2.1.7 | HexValue | read-only | The bit mask of CAPI 2.0 listen CIPMask. |
| HEX capiListenController | 1.3.6.1.4.1.272.4.7.2.1.2 | HexValue | read-only | The ISDN controller number. This value refers to the
isdnStkNumber. |
| HEX capiListenEazMask | 1.3.6.1.4.1.272.4.7.2.1.4 | HexValue | read-only | The bit mask of CAPI 1.1 listen-EAZs (CAPI 1.1 only). |
| capiListenEntry | 1.3.6.1.4.1.272.4.7.2.1 | | not-accessible | |
| HEX capiListenInfoMask | 1.3.6.1.4.1.272.4.7.2.1.5 | HexValue | read-only | The bit mask of the CAPI 1.1/2.0 listen InfoMask setting.
The purpose of infomask is to specify the type of
information for a physical connection or controller which
will be provided by CAPI. |
| HEX capiListenServiceMask | 1.3.6.1.4.1.272.4.7.2.1.3 | HexValue | read-only | The bit mask of CAPI 1.1 listen services. Specifies
which 1TR6 services to listen for (CAPI 1.1 only). |
| capiListenTable | 1.3.6.1.4.1.272.4.7.2 | | not-accessible | The capiListenTable contains the listen settings for each
CAPI application.
Creating entries: Entries can only be created by the
system and is performed automatically upon receiving a
CAPI_LISTEN_REQ message.
Deleting entries: Entries are automatically removed
by the system once the application releases. |
| capiMultiControllerEntry | 1.3.6.1.4.1.272.4.7.7.1 | | not-accessible | |
| capiMultiControllerTable | 1.3.6.1.4.1.272.4.7.7 | | not-accessible | This table contains mappings between controller numbers
used by CAPI applications and the ISDN stacks available on
the BRICK (i.e., the Number field of the isdnStkTable).
The Version field specifies whether an entry applies to
CAPI 1.1 or CAPI 2.0 applications.
If a CAPI 1.1 entry is not defined, CAPI 1.1 applications
can only use isdnStkNumber N if N is the controller number
requested by the application.
If a CAPI 2.0 entry is not defined, CAPI 2.0 applications
can only use isdnStkNumber N-1 if N is the controller number
requested by the application.
Creating entries: Entries are created by assigning a
value to the capiControllerNumber object.
Deleting entries: An entry can be removed by assigning
the value `delete' to its capiControllerVersion object. |
| INT capiNcciApplication | 1.3.6.1.4.1.272.4.7.4.1.2 | INTEGER | read-only | The application number (capiApplNumber). |
| capiNcciEntry | 1.3.6.1.4.1.272.4.7.4.1 | | not-accessible | |
| HEX capiNcciNumber | 1.3.6.1.4.1.272.4.7.4.1.1 | HexValue | read-only | The NCCI number assigned by the system. |
| HEX capiNcciPlci | 1.3.6.1.4.1.272.4.7.4.1.3 | HexValue | read-only | The CAPI PLCI number (capiPlciNumber). |
| INT capiNcciState | 1.3.6.1.4.1.272.4.7.4.1.4 | INTEGER | read-only | The current state of the NCCI, as described in the
CAPI state diagram. |
| capiNcciTable | 1.3.6.1.4.1.272.4.7.4 | | not-accessible | The capiNcciTable contains information for each CAPI
NCCI (network control connection identifier). An NCCI
describes a logical connection on level 3. Several NCCIs
operating on the same PLCI may exist.
Creating entries: As soon as a CAPI_CONNECT_B3_REQ
(or CAPI_CONNECT_B3_IND) message is received,
the system creates an entry by assigning the
application a unique capiNcciNumber.
Deleting entries: Entries are automatically deleted by
the system once a CAPI_DISCONNECT_B3_RESP
message is received. |
| INT capiPlciApplication | 1.3.6.1.4.1.272.4.7.3.1.2 | INTEGER | read-only | The application-number (capiApplNumber). |
| OCT capiPlciB1Config | 1.3.6.1.4.1.272.4.7.3.1.10 | OCTET STRING | read-only | Current CAPI 2.0 B1 protocol configuration setting. |
| INT capiPlciB1Proto | 1.3.6.1.4.1.272.4.7.3.1.9 | INTEGER | read-only | Current CAPI 2.0 B1 protocol setting. |
| OCT capiPlciB2Config | 1.3.6.1.4.1.272.4.7.3.1.12 | OCTET STRING | read-only | Current CAPI 2.0 B2 protocol configuration setting. |
| INT capiPlciB2Proto | 1.3.6.1.4.1.272.4.7.3.1.11 | INTEGER | read-only | Current CAPI 2.0 B2 protocol setting. |
| OCT capiPlciB3Config | 1.3.6.1.4.1.272.4.7.3.1.14 | OCTET STRING | read-only | Current CAPI 2.0 B3 protocol configuration setting. |
| INT capiPlciB3Proto | 1.3.6.1.4.1.272.4.7.3.1.13 | INTEGER | read-only | Current CAPI 2.0 B3 protocol setting. |
| INT capiPlciCipValue | 1.3.6.1.4.1.272.4.7.3.1.15 | INTEGER | read-only | The current CIPValue setting. |
| HEX capiPlciController | 1.3.6.1.4.1.272.4.7.3.1.3 | HexValue | read-only | The ISDN controller number. This value refers to the
isdnStkNumber. |
| capiPlciEntry | 1.3.6.1.4.1.272.4.7.3.1 | | not-accessible | |
| HEX capiPlciInfoMask | 1.3.6.1.4.1.272.4.7.3.1.16 | HexValue | read-only | The current InfoMask setting. |
| HEX capiPlciNumber | 1.3.6.1.4.1.272.4.7.3.1.1 | HexValue | read-only | The PLCI (physical link connection identifier) of the
application. |
| OCT capiPlciSelectB2Dlpd | 1.3.6.1.4.1.272.4.7.3.1.6 | OCTET STRING | read-only | Current B2 protocol descriptor. DLPD = data link
protocol descriptor (CAPI 1.1 applications only). |
| INT capiPlciSelectB2Proto | 1.3.6.1.4.1.272.4.7.3.1.5 | INTEGER | read-only | The current B2 protocol setting (CAPI 1.1 applications
only). |
| OCT capiPlciSelectB3Ncpd | 1.3.6.1.4.1.272.4.7.3.1.8 | OCTET STRING | read-only | The current B3 Ncpd setting. NCPD = network control
protocol descriptor (CAPI 1.1 applications only). |
| INT capiPlciSelectB3Proto | 1.3.6.1.4.1.272.4.7.3.1.7 | INTEGER | read-only | Current B3 protocol setting (CAPI 1.1 applications
only). |
| INT capiPlciState | 1.3.6.1.4.1.272.4.7.3.1.4 | INTEGER | read-only | The current link state as described in the CAPI state
diagram. |
| capiPlciTable | 1.3.6.1.4.1.272.4.7.3 | | not-accessible | The capiPlciTable contains information for each currently
connected CAPI application (i.e. has a Physical Link
Connection Identifier associated with it).
Creating entries: Entries can only be made by the
system. Upon receiving a CAPI_CONNECT_REQ (or
CAPI_CONNECT_IND) message, the system assigns a
unique PLCI (capiPlciNumber) and an entry is made.
Deleting entries: Entries are automatically deleted by
the system once a CAPI_DISCONNECT_RESP message
is received. |
| dod | 1.3.6 | | | |
| enterprises | 1.3.6.1.4.1 | | | |
| internet | 1.3.6.1 | | | |
| org | 1.3 | | | |
| private | 1.3.6.1.4 | | | |