BEROFIX-MIB :: berofixSystemUptime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBEROFIX-MIBberofixSystemUptime

berofixSystemUptime

Module: BEROFIX-MIB

OID (symbolic): BEROFIX-MIB::berofixSystemUptime

OID (numeric): 1.3.6.1.4.1.29886.0.9.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The uptime of this berofix-device.

What is berofixSystemUptime?

Reports how long the berofix device's system has been running since its last restart.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.29886.0.9.1
snmpwalk -v2c -c public <target> BEROFIX-MIB::berofixSystemUptime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.29886.0.9.1.1
snmpget -v2c -c public <target> BEROFIX-MIB::berofixSystemUptime.1

Start monitoring beroNet berofix VoIP gateway with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BEROFIX-MIB::berofixSystemUptime OID value, configure state conditions and alerts, and monitor any beroNet berofix VoIP gateway from a single console.

How to Use in IPNetwork Monitor

Select a beroNet berofix VoIP gateway as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type berofixSystemUptime into the Find box to locate it in the OID tree, then select it and click OK. The uptime of this berofix-device. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the value is unexpectedly low (e.g. under 10 minutes), since that indicates a recent, possibly unplanned, reboot or restart. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.29886berofixBEROFIX-MIB
1.3.6.1.4.1.29886.0berofixDeviceInfoBEROFIX-MIB
1.3.6.1.4.1.29886.0.9berofixDeviceInfoUptimeGroupBEROFIX-MIB
1.3.6.1.4.1.29886.0.9.1berofixSystemUptimeBEROFIX-MIB