BDCOM-SYS :: bdenvTestPt3Measure

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBDCOM-SYSbdenvTestPt3Measure

bdenvTestPt3Measure

Module: BDCOM-SYS

OID (symbolic): BDCOM-SYS::bdenvTestPt3Measure

OID (numeric): 1.3.6.1.4.1.3320.2.1.83

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Current value of test point 3. Typically the value in millivolts of the +5v supply

What is bdenvTestPt3Measure?

This OID reports the current value of test point 3 in millivolts, typically the +5V supply voltage. Deviations from 5000 mV indicate power supply problems. Example: a reading of 5040 means the +5V supply is delivering 5.04 volts, slightly above nominal.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3320.2.1.83
snmpwalk -v2c -c public <target> BDCOM-SYS::bdenvTestPt3Measure

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3320.2.1.83.1
snmpget -v2c -c public <target> BDCOM-SYS::bdenvTestPt3Measure.1

Start monitoring BDCOM networking equipment (switches/routers) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BDCOM-SYS::bdenvTestPt3Measure OID value, configure state conditions and alerts, and monitor any BDCOM networking equipment (switches/routers) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3320bdcomBDCOM-SMI
1.3.6.1.4.1.3320.2bdlocalBDCOM-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3320.2.1bdlsystemBDCOM-SYS
1.3.6.1.4.1.3320.2.1.83bdenvTestPt3MeasureBDCOM-SYS