All MIBs › BDCOM-SYS › bdenvTestPt2MarginVal
bdenvTestPt2MarginVal
Module: BDCOM-SYS
OID (symbolic): BDCOM-SYS::bdenvTestPt2MarginVal
OID (numeric): 1.3.6.1.4.1.3320.2.1.91
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Value at which the router will shutdown. Typically the airflow air temperature that will shut the router down. (e.g. 58)
What is bdenvTestPt2MarginVal?
This OID records the temperature threshold for test point 2 (exhaust air) above which the device will shut down. It prevents damage from excessive outlet temperatures. Example: a value of 58 means shutdown triggers if exhaust temperature reaches 58 degrees Celsius.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3320.2.1.91 snmpwalk -v2c -c public <target> BDCOM-SYS::bdenvTestPt2MarginVal
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3320.2.1.91.1 snmpget -v2c -c public <target> BDCOM-SYS::bdenvTestPt2MarginVal.1
Start monitoring BDCOM networking equipment (switches/routers) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BDCOM-SYS::bdenvTestPt2MarginVal OID value, configure state conditions and alerts, and monitor any BDCOM networking equipment (switches/routers) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.3320 | bdcom | BDCOM-SMI |
| 1.3.6.1.4.1.3320.2 | bdlocal | BDCOM-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3320.2.1 | bdlsystem | BDCOM-SYS |
| 1.3.6.1.4.1.3320.2.1.91 | bdenvTestPt2MarginVal | BDCOM-SYS |