BDCOM-SYS :: bdenvTestPt1last

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBDCOM-SYSbdenvTestPt1last

bdenvTestPt1last

Module: BDCOM-SYS

OID (symbolic): BDCOM-SYS::bdenvTestPt1last

OID (numeric): 1.3.6.1.4.1.3320.2.1.96

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Value of TestPt1 when last shutdown occurred.

What is bdenvTestPt1last?

This OID records the temperature value of test point 1 at the time of the last device shutdown. It helps diagnose what environmental condition triggered the shutdown. Example: a reading of 48 shows the ambient temperature was 48 degrees Celsius when the device last shut down.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3320.2.1.96
snmpwalk -v2c -c public <target> BDCOM-SYS::bdenvTestPt1last

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3320.2.1.96.1
snmpget -v2c -c public <target> BDCOM-SYS::bdenvTestPt1last.1

Start monitoring BDCOM networking equipment (switches/routers) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BDCOM-SYS::bdenvTestPt1last OID value, configure state conditions and alerts, and monitor any BDCOM networking equipment (switches/routers) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3320bdcomBDCOM-SMI
1.3.6.1.4.1.3320.2bdlocalBDCOM-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3320.2.1bdlsystemBDCOM-SYS
1.3.6.1.4.1.3320.2.1.96bdenvTestPt1lastBDCOM-SYS