All MIBs › AtiSwitch-MIB › atiswitchEthErrorAlignment
atiswitchEthErrorAlignment
Module: AtiSwitch-MIB
OID (symbolic): AtiSwitch-MIB::atiswitchEthErrorAlignment
OID (numeric): 1.3.6.1.4.1.207.8.15.5.2.2
Node type: OBJECT-TYPE
Type: Counter32
Access: read-only
Description: The total number of packets received that has alignment errors.
What is atiswitchEthErrorAlignment?
Counts packets received with alignment errors, meaning the frame did not end on a byte boundary and also had a CRC error. These errors usually point to physical layer problems or duplex mismatches.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.8.15.5.2.2 snmpwalk -v2c -c public <target> AtiSwitch-MIB::atiswitchEthErrorAlignment
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.207.8.15.5.2.2.1 snmpget -v2c -c public <target> AtiSwitch-MIB::atiswitchEthErrorAlignment.1
Start monitoring Allied Telesyn Layer 2/3 next-generation switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AtiSwitch-MIB::atiswitchEthErrorAlignment OID value, configure state conditions and alerts, and monitor any Allied Telesyn Layer 2/3 next-generation switches (legacy) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.207 | alliedTelesyn | AT-RG600-MIB |
| 1.3.6.1.4.1.207.8 | mibObject | AT-RG600-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.207.8.15 | atiSwitchMib | AtiSwitch-MIB |
| 1.3.6.1.4.1.207.8.15.5 | atiswitchEthernetStatsGroup | AtiSwitch-MIB |
| 1.3.6.1.4.1.207.8.15.5.2 | atiswitchEthErrorStats | AtiSwitch-MIB |
| 1.3.6.1.4.1.207.8.15.5.2.2 | atiswitchEthErrorAlignment | AtiSwitch-MIB |