AtiEdgeSwitch-MIB :: atiStkSwLldpMedRemXPoEPSEPowerSource

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAtiEdgeSwitch-MIBatiStkSwLldpMedRemXPoEPSEPowerSource

atiStkSwLldpMedRemXPoEPSEPowerSource

Module: AtiEdgeSwitch-MIB

OID (symbolic): AtiEdgeSwitch-MIB::atiStkSwLldpMedRemXPoEPSEPowerSource

OID (numeric): 1.3.6.1.4.1.207.8.17.10.4.4.1.1.21

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Defines the type of PSE Power Source advertised by the remote device.

A value primary(2) indicates that the device advertises its power source as primary.

A value backup(3) indicates that the device advertises its power Source as backup.

What is atiStkSwLldpMedRemXPoEPSEPowerSource?

Indicates the type of power source a remote PoE PSE advertises, such as primary power or backup power. This information helps determine the reliability and redundancy of power delivery from the remote device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.8.17.10.4.4.1.1.21
snmpwalk -v2c -c public <target> AtiEdgeSwitch-MIB::atiStkSwLldpMedRemXPoEPSEPowerSource

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.207.8.17.10.4.4.1.1.21.1
snmpget -v2c -c public <target> AtiEdgeSwitch-MIB::atiStkSwLldpMedRemXPoEPSEPowerSource.1

Start monitoring Allied Telesis AT-9000/AT-8100S/AT-8100L/AT-FS970M edge switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AtiEdgeSwitch-MIB::atiStkSwLldpMedRemXPoEPSEPowerSource OID value, configure state conditions and alerts, and monitor any Allied Telesis AT-9000/AT-8100S/AT-8100L/AT-FS970M edge switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.207alliedTelesynAT-RG600-MIB
1.3.6.1.4.1.207.8mibObjectAT-RG600-MIB
Numeric OIDNameModule
1.3.6.1.4.1.207.8.17atiStkSwMibAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10atiStkSwLldpGroupAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.4atiStkSwLldpRemoteDataAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.4.4atiStkSwLldpRemMedDataAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.4.4.1atiStkSwLldpMedRemTableAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.4.4.1.1atiStkSwLldpMedRemEntryAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.4.4.1.1.21atiStkSwLldpMedRemXPoEPSEPowerSourceAtiEdgeSwitch-MIB