AtiEdgeSwitch-MIB :: atiStkSwLldpDot3LocPowerPairControlable

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAtiEdgeSwitch-MIBatiStkSwLldpDot3LocPowerPairControlable

atiStkSwLldpDot3LocPowerPairControlable

Module: AtiEdgeSwitch-MIB

OID (symbolic): AtiEdgeSwitch-MIB::atiStkSwLldpDot3LocPowerPairControlable

OID (numeric): 1.3.6.1.4.1.207.8.17.10.3.3.1.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The truth value is derived from the value of pethPsePortPowerPairsControlAbility object (defined in IETF RFC 3621) and is used to indicate whether the pair selection can be controlled on the given port associated with the local system.

What is atiStkSwLldpDot3LocPowerPairControlable?

Indicates whether the power pair selection on the local switch stack port can be administratively controlled, derived from the RFC 3621 pethPsePortPowerPairsControlAbility object. When true, an administrator can choose which wire pair carries PoE power.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.8.17.10.3.3.1.1.10
snmpwalk -v2c -c public <target> AtiEdgeSwitch-MIB::atiStkSwLldpDot3LocPowerPairControlable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.207.8.17.10.3.3.1.1.10.1
snmpget -v2c -c public <target> AtiEdgeSwitch-MIB::atiStkSwLldpDot3LocPowerPairControlable.1

Start monitoring Allied Telesis AT-9000/AT-8100S/AT-8100L/AT-FS970M edge switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AtiEdgeSwitch-MIB::atiStkSwLldpDot3LocPowerPairControlable OID value, configure state conditions and alerts, and monitor any Allied Telesis AT-9000/AT-8100S/AT-8100L/AT-FS970M edge switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.207alliedTelesynAT-RG600-MIB
1.3.6.1.4.1.207.8mibObjectAT-RG600-MIB
Numeric OIDNameModule
1.3.6.1.4.1.207.8.17atiStkSwMibAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10atiStkSwLldpGroupAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.3atiStkSwLldpLocalDataAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.3.3atiStkSwLldpLocalDot3DataAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.3.3.1atiStkSwLldpDot3LocTableAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.3.3.1.1atiStkSwLldpDot3LocEntryAtiEdgeSwitch-MIB
1.3.6.1.4.1.207.8.17.10.3.3.1.1.10atiStkSwLldpDot3LocPowerPairControlableAtiEdgeSwitch-MIB