Amperion-MIB :: afeCpldResetCount

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAmperion-MIBafeCpldResetCount

afeCpldResetCount

Module: Amperion-MIB

OID (symbolic): Amperion-MIB::afeCpldResetCount

OID (numeric): 1.3.6.1.4.1.13995.11.5

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: afe Cpld Reset Count

What is afeCpldResetCount?

Reports the number of times the Analog Front End (AFE) Complex Programmable Logic Device (CPLD) has been reset, which can indicate instability or hardware issues in the PLC analog circuitry.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.13995.11.5
snmpwalk -v2c -c public <target> Amperion-MIB::afeCpldResetCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.13995.11.5.1
snmpget -v2c -c public <target> Amperion-MIB::afeCpldResetCount.1

Start monitoring Amperion broadband-over-powerline (BPL) access points and CPE modems (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Amperion-MIB::afeCpldResetCount OID value, configure state conditions and alerts, and monitor any Amperion broadband-over-powerline (BPL) access points and CPE modems (legacy) from a single console.

How to Use in IPNetwork Monitor

Select an Amperion broadband-over-powerline (BPL) access point or CPE modem (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type afeCpldResetCount into the Find box to locate it in the OID tree, then select it and click OK. It reports afe Cpld Reset Count. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.13995amperionAmperion-MIB
1.3.6.1.4.1.13995.11plcAmperion-MIB
1.3.6.1.4.1.13995.11.5afeCpldResetCountAmperion-MIB