AirPair-MIB :: modemModulatorInputFifoError

MIB Reference — IPNetwork Monitor · Updated September 12, 2026

All MIBsAirPair-MIBmodemModulatorInputFifoError

modemModulatorInputFifoError

Module: AirPair-MIB

OID (symbolic): AirPair-MIB::modemModulatorInputFifoError

OID (numeric): 1.3.6.1.4.1.7262.1.19.3.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Overrun or underrun of the FIFO contained inside the modulator. The severity is critical, the probable cause is electrical interference, and recommended course of action is to reset the modem unit, or relpace the modem unit.

What is modemModulatorInputFifoError?

This critical alarm fires when the FIFO buffer inside the modulator overruns or underruns, typically due to electrical interference; the recommended action is to reset or replace the modem unit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7262.1.19.3.10
snmpwalk -v2c -c public <target> AirPair-MIB::modemModulatorInputFifoError

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7262.1.19.3.10.1
snmpget -v2c -c public <target> AirPair-MIB::modemModulatorInputFifoError.1

Start monitoring DragonWave microwave radios with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AirPair-MIB::modemModulatorInputFifoError OID value, configure state conditions and alerts, and monitor any DragonWave microwave radios from a single console.

OID Breakdown

Upper-level ancestors (1 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
Numeric OIDNameModule
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7262dragonwaveAirPair-MIB
1.3.6.1.4.1.7262.1airPairAirPair-MIB
1.3.6.1.4.1.7262.1.19apSystemAlarmsAirPair-MIB
1.3.6.1.4.1.7262.1.19.3modemAlarmsAirPair-MIB
1.3.6.1.4.1.7262.1.19.3.10modemModulatorInputFifoErrorAirPair-MIB