ATM2-MIB :: atmSigSSCOPConEvents

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsATM2-MIBatmSigSSCOPConEvents

atmSigSSCOPConEvents

Module: ATM2-MIB

OID (symbolic): ATM2-MIB::atmSigSSCOPConEvents

OID (numeric): 1.3.6.1.2.1.37.1.14.1.3.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: SSCOP Connection Events Counter. This counter counts the sum of the following errors:

1) SSCOP Connection Disconnect Counter

The abnormal occurrence of this event is characterized by the expiry of Timer_NO_RESPONSE. (This event is communicated to the layer management with MAA-ERROR code P. See ITU-T Q.2110.)

2) SSCOP Connection Initiation Failure

This condition indicates the inability to establish an SSCOP connection. This event occurs whenever the number of expiries of the connection control timer (Timer_CC) equals or exceeds the MaxCC, or upon receipt of a connection reject message BGREJ PDU. (This event is communicated to layer management with MAA-ERROR code O. See ITU-T Q.2110.)

3) SSCOP Connection Re-Establ/Resynch

This event occurs upon receipt of a BGN PDU or RS PDU.

What is atmSigSSCOPConEvents?

This is a read-only counter tracking the cumulative SSCOP (Service Specific Connection Oriented Protocol) connection events. It counts connection disconnects and initiation failures to monitor signaling layer reliability. A value of 50 indicates 50 SSCOP connection problems have occurred.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.37.1.14.1.3.1.1
snmpwalk -v2c -c public <target> ATM2-MIB::atmSigSSCOPConEvents

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.37.1.14.1.3.1.1.1
snmpget -v2c -c public <target> ATM2-MIB::atmSigSSCOPConEvents.1

Start monitoring ATM switches/interfaces using SVC signaling with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ATM2-MIB::atmSigSSCOPConEvents OID value, configure state conditions and alerts, and monitor any ATM switches/interfaces using SVC signaling from a single console.

How to Use in IPNetwork Monitor

Select an ATM switches/interfaces using SVC signaling as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type atmSigSSCOPConEvents into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports sSCOP Connection Events Counter. This counter counts the sum of the following errors: 1) SSCOP Connection Disconnect Counter The abnormal occurrence of this event is characterized by the expiry of Timer_NO_RESPONSE. (This event is communicated to the layer management with MAA-ERROR code. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.37atmMIBATM-MIB
1.3.6.1.2.1.37.1atmMIBObjectsATM-MIB
Numeric OIDNameModule
1.3.6.1.2.1.37.1.14atm2MIBATM2-MIB
1.3.6.1.2.1.37.1.14.1atm2MIBObjectsATM2-MIB
1.3.6.1.2.1.37.1.14.1.3atmSigStatTableATM2-MIB
1.3.6.1.2.1.37.1.14.1.3.1atmSigStatEntryATM2-MIB
1.3.6.1.2.1.37.1.14.1.3.1.1atmSigSSCOPConEventsATM2-MIB