ATM2-MIB :: atmSigEmitClgPtyEvents

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsATM2-MIBatmSigEmitClgPtyEvents

atmSigEmitClgPtyEvents

Module: ATM2-MIB

OID (symbolic): ATM2-MIB::atmSigEmitClgPtyEvents

OID (numeric): 1.3.6.1.2.1.37.1.14.1.3.1.14

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Number of Calling Party Events transmitted from this interface. This counter monitors error events that occur due to the originating user doing something wrong. This counter is incremented when a RELEASE, RELEASE COMPLETE (only when not preceded by a RELEASE message for the same call), ADD PARTY REJECT, or STATUS message that contains one of the following cause code values is transmitted (Note: These cause values apply to both UNI3.0 and UNI3.1):

Cause Value Meaning

28 invalid number format (address incomplete) 43 access information discarded 57 bearer capability not authorized 65 bearer capability not implemented 73 unsupported combination of traffic parameters 78 AAL parameters cannot be supported (UNI3.1 only) 91 invalid transit network selection 93 AAL parameters cannot be supported (UNI3.0 only)

NOTE: For this counter, RELEASE COMPLETE messages that are a reply to a previous RELEASE message and contain the same cause value, are redundant (for counting purposes) and should not be counted.

What is atmSigEmitClgPtyEvents?

Counts calling party error events that were transmitted from this interface, reflecting situations where this device sent error-indicating messages such as RELEASE or STATUS ENQUIRY due to originating-party faults. Monitoring this counter helps identify when the local device is generating calling party errors toward the network.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.37.1.14.1.3.1.14
snmpwalk -v2c -c public <target> ATM2-MIB::atmSigEmitClgPtyEvents

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.37.1.14.1.3.1.14.1
snmpget -v2c -c public <target> ATM2-MIB::atmSigEmitClgPtyEvents.1

Start monitoring ATM switches/interfaces using SVC signaling with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ATM2-MIB::atmSigEmitClgPtyEvents OID value, configure state conditions and alerts, and monitor any ATM switches/interfaces using SVC signaling from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.37atmMIBATM-MIB
1.3.6.1.2.1.37.1atmMIBObjectsATM-MIB
Numeric OIDNameModule
1.3.6.1.2.1.37.1.14atm2MIBATM2-MIB
1.3.6.1.2.1.37.1.14.1atm2MIBObjectsATM2-MIB
1.3.6.1.2.1.37.1.14.1.3atmSigStatTableATM2-MIB
1.3.6.1.2.1.37.1.14.1.3.1atmSigStatEntryATM2-MIB
1.3.6.1.2.1.37.1.14.1.3.1.14atmSigEmitClgPtyEventsATM2-MIB