Description: Number of Calling Party Events detected on this interface. This counter monitors error events that occur due to the originating user doing something wrong. This counter is incremented when a RELEASE, RELEASE COMPLETE (only when not preceded by a RELEASE message for the same call), ADD PARTY REJECT, or STATUS message that contains one of the following cause code values is received (Note: These cause values apply to both UNI3.0 and UNI3.1):
Cause Value Meaning
28 invalid number format (address incomplete) 43 access information discarded 57 bearer capability not authorized 65 bearer capability not implemented
73 unsupported combination of traffic parameters 78 AAL parameters cannot be supported (UNI3.1 only) 91 invalid transit network selection 93 AAL parameters cannot be supported (UNI3.0 only)
NOTE: For this counter, RELEASE COMPLETE messages that are a reply to a previous RELEASE message and contain the same cause value, are redundant (for counting purposes) and should not be counted.
What is atmSigDetectClgPtyEvents?
Counts error events on this interface that are attributable to the originating (calling) party behaving incorrectly during call setup or teardown, such as sending unexpected RELEASE or STATUS ENQUIRY messages. A high count suggests problems with the upstream equipment or user device initiating calls.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.37.1.14.1.3.1.13 snmpwalk -v2c -c public <target> ATM2-MIB::atmSigDetectClgPtyEvents
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.37.1.14.1.3.1.13.1 snmpget -v2c -c public <target> ATM2-MIB::atmSigDetectClgPtyEvents.1
Start monitoring ATM switches/interfaces using SVC signaling with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ATM2-MIB::atmSigDetectClgPtyEvents OID value, configure state conditions and alerts, and monitor any ATM switches/interfaces using SVC signaling from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | AXON-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.37 | atmMIB | ATM-MIB |
| 1.3.6.1.2.1.37.1 | atmMIBObjects | ATM-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.37.1.14 | atm2MIB | ATM2-MIB |
| 1.3.6.1.2.1.37.1.14.1 | atm2MIBObjects | ATM2-MIB |
| 1.3.6.1.2.1.37.1.14.1.3 | atmSigStatTable | ATM2-MIB |
| 1.3.6.1.2.1.37.1.14.1.3.1 | atmSigStatEntry | ATM2-MIB |
| 1.3.6.1.2.1.37.1.14.1.3.1.13 | atmSigDetectClgPtyEvents | ATM2-MIB |