AT-SWITCH-MIB :: swiDebugMemoryParityErrors

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAT-SWITCH-MIBswiDebugMemoryParityErrors

swiDebugMemoryParityErrors

Module: AT-SWITCH-MIB

OID (symbolic): AT-SWITCH-MIB::swiDebugMemoryParityErrors

OID (numeric): 1.3.6.1.4.1.207.8.4.4.4.87.3.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: For switches based on certain switch chips, the number of parity errors that have been detected in packet memory associated with the switch. If the device does not include the counting of memory parity errors, this variable will return 0.

What is swiDebugMemoryParityErrors?

Counts parity errors detected in the packet memory of the switch chip, which can signal hardware-level memory corruption; devices without this capability always return zero.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.8.4.4.4.87.3.1
snmpwalk -v2c -c public <target> AT-SWITCH-MIB::swiDebugMemoryParityErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.207.8.4.4.4.87.3.1.1
snmpget -v2c -c public <target> AT-SWITCH-MIB::swiDebugMemoryParityErrors.1

Start monitoring Allied Telesis managed switches and routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AT-SWITCH-MIB::swiDebugMemoryParityErrors OID value, configure state conditions and alerts, and monitor any Allied Telesis managed switches and routers from a single console.

How to Use in IPNetwork Monitor

Select an Allied Telesis managed switch or router as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type swiDebugMemoryParityErrors into the Find box to locate it in the OID tree, then select it and click OK. It reports the for switches based on certain switch chips, the number of parity errors that have been detected in packet memory associated with the switch. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.207alliedTelesynAT-RG600-MIB
1.3.6.1.4.1.207.8mibObjectAT-RG600-MIB
1.3.6.1.4.1.207.8.4brouterMibAT-SMI-MIB
1.3.6.1.4.1.207.8.4.4atRouterAT-SMI-MIB
1.3.6.1.4.1.207.8.4.4.4modulesAT-SMI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.207.8.4.4.4.87swiAT-SWITCH-MIB
1.3.6.1.4.1.207.8.4.4.4.87.3swiDebugVariablesAT-SWITCH-MIB
1.3.6.1.4.1.207.8.4.4.4.87.3.1swiDebugMemoryParityErrorsAT-SWITCH-MIB