All MIBs › AT-ENVMONv2-MIB › atEnvMonv2FaultLed1Flash
atEnvMonv2FaultLed1Flash
Module: AT-ENVMONv2-MIB
OID (symbolic): AT-ENVMONv2-MIB::atEnvMonv2FaultLed1Flash
OID (numeric): 1.3.6.1.4.1.207.8.4.4.3.12.6.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This object indicates whether a fault LED is currently showing a system failure by flashing once. It indicates that one or more heatsink fans have failed, or are operating below the recommended speed.
What is atEnvMonv2FaultLed1Flash?
This read-only enumeration shows the status indicated by a single fault LED flash pattern. A value of 'heatsinkFanFailure' (1) means one or more heatsink fans have failed. A value of 'noFault' (2) means no heatsink issue.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.8.4.4.3.12.6.1.2 snmpwalk -v2c -c public <target> AT-ENVMONv2-MIB::atEnvMonv2FaultLed1Flash
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.207.8.4.4.3.12.6.1.2.1 snmpget -v2c -c public <target> AT-ENVMONv2-MIB::atEnvMonv2FaultLed1Flash.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> atEnvMonv2FaultLed1Flash.1
Start monitoring Allied Telesis switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AT-ENVMONv2-MIB::atEnvMonv2FaultLed1Flash OID value, configure state conditions and alerts, and monitor any Allied Telesis switches from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.207 | alliedTelesyn | AT-RG600-MIB |
| 1.3.6.1.4.1.207.8 | mibObject | AT-RG600-MIB |
| 1.3.6.1.4.1.207.8.4 | brouterMib | AT-SMI-MIB |
| 1.3.6.1.4.1.207.8.4.4 | atRouter | AT-SMI-MIB |
| 1.3.6.1.4.1.207.8.4.4.3 | sysinfo | AT-SMI-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.207.8.4.4.3.12 | atEnvMonv2 | AT-ENVMONv2-MIB |
| 1.3.6.1.4.1.207.8.4.4.3.12.6 | atEnvMonv2FaultLedTable | AT-ENVMONv2-MIB |
| 1.3.6.1.4.1.207.8.4.4.3.12.6.1 | atEnvMonv2FaultLedEntry | AT-ENVMONv2-MIB |