ARUBAWIRED-POE-MIB :: arubaWiredPoePethPsePortInvalidSignatureCounterPairA

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ARUBAWIRED-POE-MIB › arubaWiredPoePethPsePortInvalidSignatureCounterPairA

arubaWiredPoePethPsePortInvalidSignatureCounterPairA

Module: ARUBAWIRED-POE-MIB

OID (symbolic): ARUBAWIRED-POE-MIB::arubaWiredPoePethPsePortInvalidSignatureCounterPairA

OID (numeric): 1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.7

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This counter is incremented when the PSE state diagram enters the state SIGNATURE_INVALID, if alt_pri='a'.

What is arubaWiredPoePethPsePortInvalidSignatureCounterPairA?

Counts the number of times the PSE detected an invalid or unrecognized PD electrical signature on wire pair A of this port. A rising count may indicate a non-standard device, cabling problems, or repeated failed connection attempts.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.7
snmpwalk -v2c -c public <target> ARUBAWIRED-POE-MIB::arubaWiredPoePethPsePortInvalidSignatureCounterPairA

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.7.1
snmpget -v2c -c public <target> ARUBAWIRED-POE-MIB::arubaWiredPoePethPsePortInvalidSignatureCounterPairA.1

Start monitoring Aruba (HPE) ArubaOS-CX wired switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ARUBAWIRED-POE-MIB::arubaWiredPoePethPsePortInvalidSignatureCounterPairA OID value, configure state conditions and alerts, and monitor any Aruba (HPE) ArubaOS-CX wired switches from a single console.

How to Use in IPNetwork Monitor

Select an Aruba (HPE) ArubaOS-CX wired switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type arubaWiredPoePethPsePortInvalidSignatureCounterPairA into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This counter is incremented when the PSE state diagram enters the state SIGNATURE_INVALID, if alt_pri='a'. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.47196hpeARUBAWIRED-NETWORKING-OID
1.3.6.1.4.1.47196.4hpeNetworkingARUBAWIRED-NETWORKING-OID
1.3.6.1.4.1.47196.4.1wiredNetworkingDevicesARUBAWIRED-NETWORKING-OID
1.3.6.1.4.1.47196.4.1.1arubaOS_CXARUBAWIRED-NETWORKING-OID
1.3.6.1.4.1.47196.4.1.1.3wndFeaturesARUBAWIRED-NETWORKING-OID
1.3.6.1.4.1.47196.4.1.1.3.8arubaWiredPoeMIBARUBAWIRED-NETWORKING-OID
Numeric OIDNameModule
1.3.6.1.4.1.47196.4.1.1.3.8.1arubaWiredPoePethPsePortARUBAWIRED-POE-MIB
1.3.6.1.4.1.47196.4.1.1.3.8.1.2arubaWiredPoePethPseFourPairPortTableARUBAWIRED-POE-MIB
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1arubaWiredPoePethPseFourPairPortEntryARUBAWIRED-POE-MIB
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.7arubaWiredPoePethPsePortInvalidSignatureCounterPairAARUBAWIRED-POE-MIB