ALU-POWER-ETHERNET-MIB :: pethPsePortMPSAbsentCounter

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ALU-POWER-ETHERNET-MIB › pethPsePortMPSAbsentCounter

pethPsePortMPSAbsentCounter

Module: ALU-POWER-ETHERNET-MIB

OID (symbolic): ALU-POWER-ETHERNET-MIB::pethPsePortMPSAbsentCounter

OID (numeric): 1.3.6.1.4.1.6486.801.1.2.1.27.999.1.1.1.11

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Counts the number of times that the pethPsePortPowerMaintenanceStatus attribute changes from any value to the value mPSAbsent(3).

What is pethPsePortMPSAbsentCounter?

Counter tracking how many times the MPS signature became absent. Network ops use this to detect frequent PD disconnections. Example: A high value indicates frequent device hot-plugging.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6486.801.1.2.1.27.999.1.1.1.11
snmpwalk -v2c -c public <target> ALU-POWER-ETHERNET-MIB::pethPsePortMPSAbsentCounter

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6486.801.1.2.1.27.999.1.1.1.11.1
snmpget -v2c -c public <target> ALU-POWER-ETHERNET-MIB::pethPsePortMPSAbsentCounter.1

Start monitoring Alcatel-Lucent Enterprise OmniSwitch switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALU-POWER-ETHERNET-MIB::pethPsePortMPSAbsentCounter OID value, configure state conditions and alerts, and monitor any Alcatel-Lucent Enterprise OmniSwitch switches from a single console.

How to Use in IPNetwork Monitor

Select an Alcatel-Lucent Enterprise OmniSwitch switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type pethPsePortMPSAbsentCounter into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. Counts the number of times that the pethPsePortPowerMaintenanceStatus attribute changes from any value to the value mPSAbsent(3). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6486alcatelALCATEL-IND1-BASE
1.3.6.1.4.1.6486.801alcatelIND1BaseMIBALCATEL-IND1-BASE
1.3.6.1.4.1.6486.801.1alcatelIND1ManagementALCATEL-IND1-BASE
1.3.6.1.4.1.6486.801.1.2managementIND1SoftwareALCATEL-IND1-BASE
1.3.6.1.4.1.6486.801.1.2.1softwareIND1EntitiesALCATEL-IND1-BASE
1.3.6.1.4.1.6486.801.1.2.1.27softentIND1InLinePowerALCATEL-IND1-BASE
Numeric OIDNameModule
1.3.6.1.4.1.6486.801.1.2.1.27.999powerEthernetMIBALU-POWER-ETHERNET-MIB
1.3.6.1.4.1.6486.801.1.2.1.27.999.1pethObjectsALU-POWER-ETHERNET-MIB
1.3.6.1.4.1.6486.801.1.2.1.27.999.1.1pethPsePortTableALU-POWER-ETHERNET-MIB
1.3.6.1.4.1.6486.801.1.2.1.27.999.1.1.1pethPsePortEntryALU-POWER-ETHERNET-MIB
1.3.6.1.4.1.6486.801.1.2.1.27.999.1.1.1.11pethPsePortMPSAbsentCounterALU-POWER-ETHERNET-MIB