All MIBs › ALTEON-CS-PHYSICAL-MIB › fdbSrcTrunk
fdbSrcTrunk
Module: ALTEON-CS-PHYSICAL-MIB
OID (symbolic): ALTEON-CS-PHYSICAL-MIB::fdbSrcTrunk
OID (numeric): 1.3.6.1.4.1.1872.2.5.2.3.1.2.1.7
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Either the value '0', or the trunk number of the trunk on which a frame having a source address equal to the value of the corresponding instance has been seen. A value of '0' indicates that the source address is not associated with a trunk.
What is fdbSrcTrunk?
Indicates the trunk group number associated with the source address of an FDB entry, or 0 if the address was not learned on a trunk. This is used to determine whether a MAC address is reachable via a link aggregation trunk.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.2.3.1.2.1.7 snmpwalk -v2c -c public <target> ALTEON-CS-PHYSICAL-MIB::fdbSrcTrunk
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.2.3.1.2.1.7.1 snmpget -v2c -c public <target> ALTEON-CS-PHYSICAL-MIB::fdbSrcTrunk.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> fdbSrcTrunk.1
Start monitoring Alteon (Nortel/Radware) Cheetah-based application switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALTEON-CS-PHYSICAL-MIB::fdbSrcTrunk OID value, configure state conditions and alerts, and monitor any Alteon (Nortel/Radware) Cheetah-based application switches (legacy) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1872 | alteon | ALTEON-PRIVATE-MIBS |
| 1.3.6.1.4.1.1872.2 | private_mibs | ALTEON-PRIVATE-MIBS |
| 1.3.6.1.4.1.1872.2.5 | aws_switch | ALTEON-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1872.2.5.2 | layer2 | ALTEON-CS-PHYSICAL-MIB |
| 1.3.6.1.4.1.1872.2.5.2.3 | layer2Info | ALTEON-CS-PHYSICAL-MIB |
| 1.3.6.1.4.1.1872.2.5.2.3.1 | fdbInfo | ALTEON-CS-PHYSICAL-MIB |
| 1.3.6.1.4.1.1872.2.5.2.3.1.2 | fdbTable | ALTEON-CS-PHYSICAL-MIB |
| 1.3.6.1.4.1.1872.2.5.2.3.1.2.1 | fdbEntry | ALTEON-CS-PHYSICAL-MIB |
| 1.3.6.1.4.1.1872.2.5.2.3.1.2.1.7 | fdbSrcTrunk | ALTEON-CS-PHYSICAL-MIB |